International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

FlexMO, HubMO SS and HubMO motor operators for high-voltage disconnectors, 20000 in-lb

The FlexMO, HubMO SS and HubMO motor operators drive disconnectors and load break switches in substations, transmission lines and distribution networks. These are self-contained electromechanical units in a cabinet, with torque up to 20000 in-lb and an operating time of 4 to 6 or 8 to 10 seconds.

Type
self-contained electric motor operator for disconnectors
Working torque
up to 20000 in-lb
Operating time
4 to 6 s; 8 to 10 s (programmable)
Control voltage, FlexMO
24, 48, 125 VDC

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The operator is mounted on the support or frame of the disconnector and coupled to its vertical operating pipe (VOP). It turns the pipe to open and close the switch on command, either from the site or remotely, including from a SCADA system. A hand crank is provided for manual operation, and the motor is interlocked whenever the handle is inserted.

The range has three versions. FlexMO is a solid state operator with battery back-up at 24 V, designed for switching devices from 15 kV to 765 kV, including those that need two-speed closing, and also for distribution disconnectors. HubMO SS is a solid state operator for substation disconnectors, with VOP position control in 5% steps. HubMO is a substation operator with a cam-operated control system, a torque of 10k to 20k in-lb and a 125 VDC supply.

In the solid state versions, an IGBT driver controls the motor, and a built-in position sensor shows the VOP position in real time, which simplifies setting the open and closed points. FlexMO adjusts its speed even during the operation and damps the inertia at the end of travel, so that the blades of the disconnector do not swing. The controller display shows position, local or remote mode, supply voltage, temperature, the operation counter and the motor status.

Standard equipment includes up to 12 adjustable auxiliary relays, dynamic braking, three types of motor overload protection, circuit breakers for the motor, controller and heater, a thermostatically controlled heater, a programmable operating delay, a software-selectable direction of rotation, local-only or remote-only operating modes, an open-door alarm and alarms for AC and DC supply voltage. The 2 inch IPS coupling on the pipe can be locked with a padlock. Optional extras are battery monitoring, pre-wired harnesses for telemetry units and a radio modem.

The cabinet is made of powder-coated galvanised steel or aluminium to NEMA 3R, or of stainless steel to NEMA 4X. The doors are removable, the cabinet is ventilated, and the terminals are mounted on a DIN rail.

Technical specifications

Typeself-contained electric motor operator for disconnectors
Working torqueup to 20000 in-lb
Operating time4 to 6 s; 8 to 10 s (programmable)
Control voltage, FlexMO24, 48, 125 VDC
Control voltage, HubMO SS48, 125 VDC
Control voltage, HubMO125 VDC
Torque, HubMO10k–20k in-lb
Switch rating, FlexMO15 kV – 765 kV
Auxiliary relaysup to 12, adjustable
VOP coupling2 inch IPS, padlockable
Cabinetpowder-coated galvanised steel (NEMA 3R), aluminium (NEMA 3R), stainless steel (NEMA 4X)
CommunicationSCADA
Back-up power (option)24 V battery

Request a price and lead time

FlexMO, HubMO SS and HubMO motor operators for high-voltage disconnectors, 20000 in-lb. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Is FlexMO suitable for distribution disconnectors?

Yes. FlexMO is rated for switching devices from 15 kV to 765 kV, including distribution disconnectors, so one type of operator can be fitted to different disconnectors.

Which supply voltages are used for the control circuits?

FlexMO works from 24, 48 and 125 VDC, HubMO SS from 48 and 125 VDC, and HubMO from 125 VDC.

Can the disconnector be operated without power?

Yes. A hand crank is supplied, and the motor is interlocked while the handle is inserted. FlexMO also has back-up power from a 24 V battery.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides