BPFR11P Fused Bypass Switch, Right-Hand Opening, 15 kV, 110 kV BIL, 600 A, 100 A Fuse
The BPFR11P is a BPF bypass switch for bypassing and isolating substation reclosers during planned maintenance. A 600 A load switch is connected in series with a Type C fuse, which protects the line against overcurrent while the recloser is out of service.
- Type
- Fused bypass load switch
- Maximum voltage
- 15 kV
- Minimum reference voltage
- 14.4 kV
- BIL
- 110 kV
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
BPF bypass switches are installed alongside a recloser at a distribution substation. During maintenance the recloser is bypassed and isolated, and the line is supplied through the bypass circuit with its fuse. A separately mounted M3S disconnector is usually fitted alongside the BPF. Operation is carried out with an insulated operating pole.
The construction consists of a 600 A load switch and a Type C fuse holder connected in series. Both devices are mounted on a common mounting channel, so they are installed as a single assembly. In the BPFR11P version the 100 A fuse holder is on the right, and the series also offers a left-hand fuse holder position and 200 A fuse holders. Station-class insulators are in Sky Grey porcelain, the blade is solid copper in a two-blade truss-member design, and the contacts are silver-plated. The base is steel galvanised to ASTM A153.
The rating is 15 kV maximum with a minimum reference voltage of 14.4 kV, and a basic insulation level (BIL) of 110 kV. The creepage distance is 393.7 mm and the interrupting rating is 10,000 A. The switch circuit withstands 25 kA symmetrical for 1 second and 65 kA peak for 10 cycles, and it allows an emergency overload of 1080 A for 8 hours. The maximum temperature rise is 25.7 °C in the switch circuit at 600 A and 15.9 °C in the fuse circuit.
The fuse holder has a single-vent design with a solid cap and takes universal fuse links, and the internal arc-quenching liner is made of synthetic material. The replacement fuse holder is designated T710-112T. The switch complies with ANSI/IEEE C37.41 and C37.42 (2016 edition) and other applicable ANSI/IEEE standards. The BPF series is also produced at 27 kV with a 150 kV BIL.
Technical specifications
| Type | Fused bypass load switch |
|---|---|
| Maximum voltage | 15 kV |
| Minimum reference voltage | 14.4 kV |
| BIL | 110 kV |
| Switch rated current | 600 A |
| Fuse holder | Type C, 100 A, right-hand |
| Interrupting rating | 10,000 A |
| Short-time withstand current | 25 kA symmetrical, 1 second |
| Peak withstand current | 65 kA peak, 10 cycles |
| Emergency overload | 1080 A, 8 hours |
| Temperature rise, switch circuit at 600 A | 25.7 °C |
| Temperature rise, fuse circuit | 15.9 °C |
| Creepage distance | 393.7 mm |
| Blade | Solid copper, two-blade truss-member design |
| Contacts | Silver-plated |
| Base | Galvanised steel, ASTM A153 |
| Insulator colour | Sky Grey |
| Replacement fuse holder | T710-112T |
| Standards | ANSI/IEEE C37.41, C37.42, 2016 edition |
Part numbers
Show all part numbers (1)
BPFR11P
Request a price and lead time
BPFR11P Fused Bypass Switch, Right-Hand Opening, 15 kV, 110 kV BIL, 600 A, 100 A Fuse. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Is the line protected against overcurrent while the recloser is out of service?
Yes, a Type C fuse rated 100 A is connected in series with the switch in the bypass circuit.
Which replacement fuse holder fits the BPFR11P?
The replacement fuse holder is designated T710-112T.
Are versions with a left-hand fuse holder or a larger current available?
Yes, the BPF series has left-hand and right-hand fuse holder positions, with 100 A and 200 A fuse holders.
Similar equipment from other manufacturers