VACUTAP VV vacuum OLTC for 40–145 kV transformers

Compact VACUTAP VV vacuum on-load tap changer for small and medium power transformers with Um 40–145 kV, including 110 kV distribution substations. Through current is up to 600 A in three-phase and up to 400 A in single-phase design.

Highest voltage for equipment Um
40–145 kV
Rated through current
up to 600 A (3-phase), up to 400 A (1-phase)
Step voltage
up to 2000 V
Step capacity
up to 700 kVA

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Step voltage is up to 2000 V and step capacity up to 700 kVA. The number of positions is up to 12 without a pre-selector and up to 23 with a pre-selector. The tap changer is installed in the neutral (three-phase design) or at any point of the winding. Its compact dimensions simplify the layout of 110 kV transformers for distribution substations.

Technical specifications

Highest voltage for equipment Um40–145 kV
Rated through currentup to 600 A (3-phase), up to 400 A (1-phase)
Step voltageup to 2000 V
Step capacityup to 700 kVA
Number of positionsup to 12 without pre-selector, up to 23 with pre-selector
Applicationin the neutral (3-phase) or at any point of the winding

Replacement for

no direct analogue (vacuum OLTCs) exists; the closest are OLTCs of type РНОА-110/1000, РНТА-35/200, РС-4, РС-9

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

VACUTAP VV vacuum OLTC for 40–145 kV transformers. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8535 90 00 00
HS, 6 digits8535 90
CN (EU)8535 90 00
HTSUS (USA)8535 90 80 60
China customs tariff8535 90 00 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Is the VACUTAP VV suitable for 110 kV transformers?

Yes, the Um range of 40–145 kV covers transformers of 110 kV distribution substations.

What are the current and step capacity of the OLTC?

Up to 600 A in three-phase and up to 400 A in single-phase design, step capacity up to 700 kVA, step voltage up to 2000 V.

Where in the winding is the tap changer installed?

In the neutral (three-phase design) or at any point of the winding.