International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

VACUTAP VR / VRL vacuum OLTC for power transformers 72.5–420 kV

Tank-integrated VACUTAP VR vacuum on-load tap changer for grid and power plant transformers 72.5–420 kV. The single-phase VRL design is rated for currents up to 3200 A, including furnace transformers.

Highest voltage for equipment Um
72.5–420 kV
Rated through current
up to 1600 A (3-phase), up to 2600 A (1-phase); VRL up to 3200 A (1-phase)
Step voltage
up to 6000 V
Step capacity
up to 6000 kVA (VRL up to 10000 kVA)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Through current of the VR is up to 1600 A in three-phase and up to 2600 A in single-phase design. Step voltage is up to 6000 V and step capacity up to 6000 kVA, up to 10000 kVA for the VRL. The number of positions is up to 18 without a pre-selector and up to 35 with a pre-selector. The switching principle is high-speed resistor type, with the arc extinguished in vacuum interrupters.

Technical specifications

Highest voltage for equipment Um72.5–420 kV
Rated through currentup to 1600 A (3-phase), up to 2600 A (1-phase); VRL up to 3200 A (1-phase)
Step voltageup to 6000 V
Step capacityup to 6000 kVA (VRL up to 10000 kVA)
Number of positionsup to 18 without pre-selector, up to 35 with pre-selector
Principlehigh-speed resistor type, vacuum interrupters

Replacement for

no direct analogue (vacuum OLTCs) exists; the closest are OLTCs of type РНОА-110/1000, РНТА-35/200, РС-4, РС-9

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

VACUTAP VR / VRL vacuum OLTC for power transformers 72.5–420 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8535 90 00 00
HS, 6 digits8535 90
CN (EU)8535 90 00
HTSUS (USA)8535 90 80 60
China customs tariff8535 90 00 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What voltage classes is the VACUTAP VR designed for?

Um 72.5–420 kV, for grid and power plant transformers.

Which design suits furnace transformers?

The single-phase VRL for currents up to 3200 A with step capacity up to 10000 kVA.

How many positions does the OLTC have?

Up to 18 without a pre-selector and up to 35 with a pre-selector.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides