VACUTAP RMV-II reactor-type vacuum OLTC 70 kV

Bolt-on reactor-type VACUTAP RMV-II on-load tap changer with vacuum interrupters for Um 70 kV and through current up to 2500 A. Developed for the North American market, it is used for grid and furnace transformers, including retrofits.

Highest voltage for equipment Um
70 kV
Rated through current
up to 2500 A
Step voltage
up to 1000 V
Step capacity
3500 / 1625 kVA (1-phase/3-phase)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Step voltage is up to 1000 V. Step capacity is 3500 kVA for single-phase and 1625 kVA for three-phase design. The number of positions is up to 17 without a pre-selector and up to 33 with a pre-selector. The unit is bolted to the tank (bolt-on), so it is convenient to fit to transformers that are already in service.

Technical specifications

Highest voltage for equipment Um70 kV
Rated through currentup to 2500 A
Step voltageup to 1000 V
Step capacity3500 / 1625 kVA (1-phase/3-phase)
Number of positionsup to 17 without pre-selector, up to 33 with pre-selector
Principlereactor type, bolt-on, vacuum interrupters

Replacement for

no direct analogue (vacuum OLTCs) exists; the closest are OLTCs of type РНОА-110/1000, РНТА-35/200, РС-4, РС-9

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

VACUTAP RMV-II reactor-type vacuum OLTC 70 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8535 90 00 00
HS, 6 digits8535 90
CN (EU)8535 90 00
HTSUS (USA)8535 90 80 60
China customs tariff8535 90 00 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

How does the RMV-II differ from resistor-type OLTCs?

It is a reactor-type OLTC with vacuum interrupters, in the bolt-on design.

What are the main parameters of the tap changer?

Um 70 kV, through current up to 2500 A, step voltage up to 1000 V. Up to 17 positions without a pre-selector and up to 33 with a pre-selector.

Is the RMV-II suitable for transformer retrofits?

Yes, it is used for grid and furnace transformers, including retrofits.