DEETAP SPT in-line de-energized tap changer 72.5–245 kV

The compact in-line DEETAP SPT de-energized tap changer is designed for small and medium power transformers with Um 72.5–245 kV. It is mounted on the winding side, with a manual or motor drive.

Highest voltage for equipment Um
SPTM: 72.5–170 kV; SPTL: 72.5–245 kV
Rated through current
SPTM 600 A, SPTL 800 A
Number of phases
1 / 3
Number of positions
up to 11 / 9 (special up to 20)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The series is divided into SPTM with Um 72.5–170 kV and a through current of 600 A, and SPTL with Um 72.5–245 kV and a current of 800 A. The tap changer is available in single-phase and three-phase versions. The number of positions is up to 11 or 9, and up to 20 in the special version. The in-line connection and winding-side mounting make the tap changer compact, which is convenient in transformers with limited dimensions.

Technical specifications

Highest voltage for equipment UmSPTM: 72.5–170 kV; SPTL: 72.5–245 kV
Rated through currentSPTM 600 A, SPTL 800 A
Number of phases1 / 3
Number of positionsup to 11 / 9 (special up to 20)
Drivemanual or motor

Replacement for

no direct analog by series; de-energized tap changers (DETC) of ТМ/ТДН transformers are a general type

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

DEETAP SPT in-line de-energized tap changer 72.5–245 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8535 90 00 00
HS, 6 digits8535 90
CN (EU)8535 90 00
HTSUS (USA)8535 90 80 60
China customs tariff8535 90 00 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

How do the SPTM and SPTL versions differ?

SPTM is rated for Um 72.5–170 kV and 600 A, SPTL for Um 72.5–245 kV and 800 A.

How many positions does the DEETAP SPT have?

Up to 11 or 9 positions, and up to 20 in the special version.

What drive operates the tap changer?

Manual or motor drive, at the customer's choice.

Similar equipment from other manufacturers