COMTAP ARS de-energized reversing switch 123–170 kV

The COMTAP ARS de-energized switch (reversing switch) changes the connection or the range of the windings of 123–170 kV power transformers. Through current is up to 2400 A in the single-phase version and up to 1800 A in the three-phase version.

Highest voltage for equipment Um
123–170 kV
Rated through current
up to 2400 A (1-phase), up to 1800 A (3-phase)
Number of positions
2 (special 3)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The device changes the connection or the range of the windings with the transformer disconnected and is not operated under load. The standard version has 2 positions, the special version 3. The reversing switch is selected for power transformers of the Um 123–170 kV class, where the winding connection is changed when putting the unit into service or when the network mode changes. The rated through current depends on the number of phases of the device.

Technical specifications

Highest voltage for equipment Um123–170 kV
Rated through currentup to 2400 A (1-phase), up to 1800 A (3-phase)
Number of positions2 (special 3)

Replacement for

no direct analog; the closest are РНОА/РНТА OLTCs with a preselector (reversing switch)

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

COMTAP ARS de-energized reversing switch 123–170 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8535 90 00 00
HS, 6 digits8535 90
CN (EU)8535 90 00
HTSUS (USA)8535 90 80 60
China customs tariff8535 90 00 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What transformers is the COMTAP ARS intended for?

For power transformers with a highest voltage Um of 123–170 kV where the winding connection or range must be switched.

What is the through current of the reversing switch?

Up to 2400 A in the single-phase version and up to 1800 A in the three-phase version.

How many positions does the switch have?

2 positions as standard and 3 in the special version.