CAPT de-energized tap changers for distribution and medium transformers 15–72.5 kV

The CAPT line of de-energized tap changers for distribution transformers (series 085–099) and medium power transformers (010, 020, 040) with Um 15–72.5 kV. Through current is 10–1500 A, with 2–11 positions.

Highest voltage for equipment Um
15–72.5 kV (series 085–099: 24–36 kV; 010/020/040: up to 72.5 kV)
Rated through current
10–1500 A
Number of positions
2–11 (special up to 20)
Schemes
bridge, in-line, neutral, series-parallel, star-delta, voltage changeover

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Series 085–099 are rated for Um 24–36 kV, and series 010, 020 and 040 for voltages up to 72.5 kV. In the special version the number of positions reaches 20. The tap changer is assembled for the required connection: bridge, in-line, neutral, series-parallel, star-delta or voltage changeover. The model range includes CAPT 010, 020, 040, 085, 086, 090, 095, 096 and 099.

Technical specifications

Highest voltage for equipment Um15–72.5 kV (series 085–099: 24–36 kV; 010/020/040: up to 72.5 kV)
Rated through current10–1500 A
Number of positions2–11 (special up to 20)
Schemesbridge, in-line, neutral, series-parallel, star-delta, voltage changeover
ModelsCAPT 010, 020, 040, 085, 086, 090, 095, 096, 099

Replacement for

no direct analog by series; de-energized tap changers (DETC) of ТМ/ТДН transformers are a general type

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

CAPT de-energized tap changers for distribution and medium transformers 15–72.5 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8535 90 00 00
HS, 6 digits8535 90
CN (EU)8535 90 00
HTSUS (USA)8535 90 80 60
China customs tariff8535 90 00 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Which CAPT series are fitted to distribution transformers?

Series 085–099 with Um 24–36 kV. Series 010, 020 and 040 are intended for medium power transformers up to 72.5 kV.

What are the through current and the number of positions?

Current 10–1500 A, 2–11 positions, up to 20 in the special version.

What switching schemes does the CAPT support?

Bridge, in-line, neutral, series-parallel, star-delta and voltage changeover.