S20 / S22 / SBH25 10 kV oil-immersed distribution transformers (stacked-core, wound-core, amorphous, smart)
S20, S22 and SBH25 are oil-immersed 10/0.4 kV distribution transformers of the first energy-efficiency class, rated 200–630 kVA. The series have a stacked, three-dimensional wound or amorphous core, and a smart version with sensors is available.
- Series
- S13, S20, S22 (stacked core); S22-M·RL (three-dimensional limb core); SBH25-M·RL (amorphous, OLTC); S20-M·ZN (smart)
- Voltage
- (10 ±2×2.5 %)/0.4 kV, Dyn11
- Ratings (examples)
- 200, 400, 630 kVA
- Losses S22-M-630
- no-load ≤460 W, short-circuit ≤4460 W
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Oil-immersed 10/0.4 kV distribution transformers are installed in urban and rural distribution networks. All series belong to the first, highest energy-efficiency class under Chinese standards. The voltage is (10 ±2×2.5 %)/0.4 kV, vector group Dyn11, cooling natural oil (ONAN), insulation LI75 AC35 kV. Typical ratings in the range are 200, 400 and 630 kVA, and noise is 45–48 dB(A) depending on the version.
The basic S13, S20 and S22 have a stacked magnetic core and a hermetically sealed tank. The S22-M-630/10 rated 630 kVA has a no-load loss of up to 460 W, a short-circuit loss of up to 4460 W, a short-circuit voltage of 4 % and noise of 48 dB(A). The units are little sensitive to harmonics, run quietly, need no lifting of the active part and require no maintenance.
In the S22-M·RL the magnetic core is a three-dimensional, triangular wound core. The three-phase magnetic system is symmetrical, with no joints or air gaps, so no-load loss and current, noise and stray fields are lower, and short-circuit and harmonic withstand is higher. The S22-M·RL-400/10 rated 400 kVA has a no-load loss of up to 330 W and a short-circuit loss of up to 3250 W; the manufacturer recommends it for replacing obsolete transformers.
The amorphous series SZBH13, SZBH21 and SBH25 combine a three-dimensional wound core of amorphous alloy with a wide-range OLTC and improve voltage quality in 0.4 kV networks. According to the manufacturer, this combination of technologies was applied for the first time in a transformer of this energy-efficiency class. The SBH25-M·RL-200/10 rated 200 kVA has a no-load loss of up to 120 W, a short-circuit loss of up to 2330 W and noise of 45 dB(A); the regulating device with intelligent control is convenient to maintain.
The smart S20-M·ZN-400/10 is equipped with sensors for voltage, current, oil and ambient temperature, pressure, oil moisture content and hydrogen. The software stores, displays and analyses the data, transmits it digitally, and provides alarms and fault self-diagnostics. No-load loss is up to 370 W and short-circuit loss up to 3615 W. The transformers of the range work in distribution networks, packaged substations, renewable energy stations, and industrial and municipal facilities.
Technical specifications
| Series | S13, S20, S22 (stacked core); S22-M·RL (three-dimensional limb core); SBH25-M·RL (amorphous, OLTC); S20-M·ZN (smart) |
|---|---|
| Voltage | (10 ±2×2.5 %)/0.4 kV, Dyn11 |
| Ratings (examples) | 200, 400, 630 kVA |
| Losses S22-M-630 | no-load ≤460 W, short-circuit ≤4460 W |
| Losses S22-M·RL-400 | no-load ≤330 W, short-circuit ≤3250 W |
| Losses SBH25-M·RL-200 | no-load ≤120 W, short-circuit ≤2330 W |
| Noise | 45–48 dB(A) |
| Design | hermetically sealed, ONAN, no need to open the active part |
Replacement for
ТМГ-250/10, ТМГ-400/10, ТМГ-630/10, ТМГ-1000/10, ТМГ-1600/10, ТМГ-2500/10; ТМ-…/10, ТМЗ-…/10; energy-efficient ТМГ11, ТМГ12
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
S20 / S22 / SBH25 10 kV oil-immersed distribution transformers (stacked-core, wound-core, amorphous, smart). We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8504 21 00 00 8504 22 10 00 |
|---|---|
| HS, 6 digits | 8504 21 |
| CN (EU) | 8504 21 00 8504 22 10 |
| HTSUS (USA) | 8504 21 00 00 8504 22 00 40 |
| China customs tariff | 8504 21 00 00 8504 22 00 00 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
What losses does the S22-M-630/10 have?
No-load loss of up to 460 W, short-circuit loss of up to 4460 W. Short-circuit voltage 4 %, noise 48 dB(A).
What is the advantage of the three-dimensional wound core of the S22-M·RL?
The magnetic system is symmetrical, with no joints or gaps, so losses and noise are lower. The S22-M·RL-400/10 rated 400 kVA has a no-load loss of up to 330 W and a short-circuit loss of up to 3250 W.
What does the smart S20-M·ZN-400/10 monitor?
Voltage, current, oil and ambient temperature, pressure, oil moisture content and hydrogen. No-load loss up to 370 W, short-circuit loss up to 3615 W.
Similar equipment from other manufacturers