International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Pad-mount transformers (outdoor single-block) up to 138 kV / 50 MVA

Pad-mount transformers are outdoor single-block transformers on a foundation, in a closed protected enclosure with high- and low-voltage compartments, intended for cable distribution networks, solar and wind power plants, commercial and industrial facilities

Voltage
up to 138 kV; primary insulation class 35 kV, BIL ≤ 200 kV
Power
up to 50 MVA; dead-front radial feed 500–3750 kVA
HV/LV (example)
12,470–24,940 V / 480/277 or 208/120 V
Frequency
60 Hz (50 Hz optional)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Pad-mount transformers are outdoor single-block transformers on a foundation, in a closed protected enclosure with high- and low-voltage compartments, intended for cable distribution networks, solar and wind power plants, commercial and industrial facilities, primarily in markets oriented to ANSI/IEEE standards. Characteristics (manufacturer's catalogue 2019): voltage up to 138 kV, power up to 50 MVA; frequency 60 Hz as standard and 50 Hz optional; insulating liquids: mineral oil, silicone oil or vegetable FR3; voltage regulation with de-energized tap changers (DETC) and on-load tap changers (OLTC); primary winding insulation of class 35 kV with BIL 200 kV and below. Impedance voltage is 2.8–5.0 % for 300–500 kVA and 5.75 % for 750–2500 kVA; for 3000–7500 kVA it is agreed with the manufacturer. A typical range with dead-front radial feed has ratings from 500 to 3750 kVA, HV voltages from 12,470 to 24,940 V and LV 480/277 V or 208/120 V; weight is from 4,600 to 16,000 lb (about 2.1–7.3 t). The dead-front design excludes accessible live parts when the compartment is open, which is important for installation in public places. Standards: ANSI, IEEE, NEMA, IEC. Production takes place at plants with an ISO 9001 quality system; tests are carried out in the company's own institute PT&T. Applications: step-up transformers for solar and wind power inverters, connection of energy storage, cable networks of residential and commercial districts, industrial sites and data centres, where compact outdoor installation without a separate substation building is required. The use of vegetable FR3 oil increases fire safety and reduces environmental risks. Parameters of a specific version are agreed with the manufacturer under the technical specification.

Technical specifications

Voltageup to 138 kV; primary insulation class 35 kV, BIL ≤ 200 kV
Powerup to 50 MVA; dead-front radial feed 500–3750 kVA
HV/LV (example)12,470–24,940 V / 480/277 or 208/120 V
Frequency60 Hz (50 Hz optional)
Insulating liquidmineral oil, silicone oil, FR3 (vegetable)
Tap changingoff-circuit (DETC) and on-load (OLTC)
Impedance voltage2.8–5.0 % (300–500 kVA); 5.75 % (750–2500 kVA)
Weight4,600–16,000 lb
StandardsANSI, IEEE, NEMA, IEC

Replacement for

КТП-…/10/0,4, КТПН, КТПБ-35/10, КТПБ-110/10 (block substations); there are no single-block 110 kV units

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

Pad-mount transformers (outdoor single-block) up to 138 kV / 50 MVA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides