Quadri*Sil 69 kV horizontal line post insulator in hydrophobic silicone, 2.5 in rod

Horizontal line post insulators with a hydrophobic silicone housing, used on 69 kV overhead lines to carry the conductor straight off the pole. Standard Leak and Extra High Leak versions are offered, with aluminium or steel bases.

Voltage class
69 kV
Type
horizontal line post
Housing
hydrophobic silicone, > 3 mm thick
Rod diameter
2.5 in

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Choosing between the two housing profiles comes down to pollution. Standard Leak units have uniform sheds; Extra High Leak units use alternating sheds and a longer creepage path for coastal, industrial or dusty routes. Both are built on a 2.5 in rod with 18 sheds and a silicone housing more than 3 mm thick.

A horizontal post works in bending, so the cantilever figures decide the span and conductor it can take. Across the listed parts the maximum cantilever strength runs from 5000 to 5960 lb and the routine load from 2500 to 2980 lb. Part P250021S0030 adds a tensile rating of 15000 lb, a creepage distance of 1448 mm (57 in) and a dry arc distance of 571 mm (22.5 in).

The live end carries a two-hole tear drop blade for the conductor clamp. Bases come in aluminium or steel, either as a gain base for direct pole fixing or as a flat plate. Holes take 7/8 in bolts on 12 in centres, and the flat bases also offer 8 × 10 in and 8 × 13 in patterns. Effective length on the core parts is 34.4–34.6 in.

Line designers can send us the conductor loading, pollution level and pole type, and we will shortlist the right part numbers.

Technical specifications

Voltage class69 kV
Typehorizontal line post
Housinghydrophobic silicone, > 3 mm thick
Rod diameter2.5 in
Number of sheds18
VersionsStandard Leak, Extra High Leak
Cantilever strength, max.5000–5960 lb
Cantilever strength, routine2500–2980 lb
Tensile strength15000 lb
Creepage (P250021S0030)1448 mm (57 in)
Dry arc distance (P250021S0030)571 mm (22.5 in)
Effective length34.4–34.6 in
Live-end fittingtear drop blade, two holes
Basealuminium or steel, gain or flat, 7/8 in bolts

How it compares with similar models

ParameterQuadri*Sil 69 kV horizontal line post insulator in hydrophobic silicone, 2.5 in rodQuadri*Sil Braced Line Post Insulator, Silicone, 138–230 kVQuadri*Sil Pivoting Horizontal V Assembly, Braced Line Post, Silicone, 138–230 kVQuadri*Sil Horizontal V Assembly, Braced Line Post, Silicone, 138–230 kV, Flat or Gain Base
Voltage class69 kV115/138, 161, 230 kV115/138, 161, 230 kV115/138, 161, 230 kV
Typehorizontal line postbraced line post insulatorpivoting horizontal V assemblyhorizontal V assembly
Tensile strength15000 lb7500 lb7500 lb7500 lb

Request a price and lead time

Quadri*Sil 69 kV horizontal line post insulator in hydrophobic silicone, 2.5 in rod. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which version suits a polluted route?

Extra High Leak, with alternating sheds and a longer creepage path than the uniform-shed Standard Leak design.

What bending load can the insulator take?

Maximum cantilever strength is 5000–5960 lb and routine load 2500–2980 lb, depending on the part number.

How is it fixed to the pole?

Through an aluminium or steel gain or flat base, using 7/8 in bolts on 12 in centres.