International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Flex Plus AC Station for Electric Vehicles, 7.4/11 kW, Type 2

Single-port wall-mounted AC station of the Flex series for charging electric vehicles at workplaces, in fleet depots and in car parks. Output reaches 7.4 kW from a 230 V single-phase feed or 11 kW from a 400 V three-phase feed, connects by LTE, Wi-Fi or Ethernet and runs the OCPP 2.0.1 protocol.

Output power
up to 7.4 kW (single-phase, 32 A); up to 11 kW (three-phase, 16 A)
Supply (±10%)
230 V, 50 Hz (single-phase); 400 V, 50 Hz (three-phase)
Connector
IEC 62196-2 Type 2: socket, shuttered socket or fixed cable
Cable length
5 m, 7.5 m

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Sites where cars stay parked for several hours suit this station best: overnight charging of company fleets, staff parking by offices, commercial property, retail centres, residential blocks with allocated bays, and logistics or passenger transport depots. It has one port on alternating current, and vehicles connect through an IEC 62196-2 Type 2 socket.

Three connection styles are offered. The CP810 has a Type 2 socket, the CP840 adds a shuttered socket, and the CP830 has a Type 2 cable permanently attached, supplied in 5 metre or 7.5 metre lengths. Each style comes in a single-phase 32 A version delivering up to 7.4 kW and a three-phase 16 A version delivering up to 11 kW. Models marked with B and the MTR suffix carry a display measuring 3.5 inches, with capacitive buttons, and Eichrecht certification for commercial metering of dispensed energy. Every variant meets MID requirements for the meter.

Links are an LTE Category 4 cellular modem, Wi-Fi on 2.4 and 5 GHz, an RJ45 Ethernet port and Bluetooth 5.0. Firmware is updated remotely, and a management platform talks to the station over OCPP 2.0.1. ISO 15118 supports Plug and Charge, and users can authorise with RFID cards to ISO/IEC 15693 and ISO/IEC 14443, with NFC on a phone, or through a mobile application.

For dynamic load management, the station connects to the building meter through MODBUS RTU, P1 DSMR, EnWG or Linky (RJ12), or through MODBUS TCP on RJ45. Current transformer accessories are supplied separately. This lets several stations share the available supply capacity without overloading it.

Protection includes built-in 6 mA DC residual current detection, an IP56 enclosure and IK10 impact resistance. The operating range is -25 to +50 °C, with humidity up to 95% at 50 °C, non-condensing. Supply is 230 V 50 Hz single-phase or 400 V 50 Hz three-phase, with a tolerance of ±10%. It mounts on a wall through a backplate, and an LED indicator shows the charging state. Certifications include CE, UKCA, EV READY, MID and Eichrecht.

Technical specifications

Output powerup to 7.4 kW (single-phase, 32 A); up to 11 kW (three-phase, 16 A)
Supply (±10%)230 V, 50 Hz (single-phase); 400 V, 50 Hz (three-phase)
ConnectorIEC 62196-2 Type 2: socket, shuttered socket or fixed cable
Cable length5 m, 7.5 m
Number of ports1
Leakage protectionbuilt-in 6 mA DC residual current detection
Ingress and impact protectionIP56, IK10
Operating temperature-25 to +50 °C
Humidityup to 95% at 50 °C, non-condensing
ProtocolsOCPP 2.0.1, ISO 15118
ConnectivityLTE Category 4; Wi-Fi on 2.4 and 5 GHz; RJ45 Ethernet; Bluetooth 5.0
AuthorisationRFID ISO/IEC 15693, ISO/IEC 14443; NFC; mobile app
Meter connectionMODBUS RTU, P1 DSMR, EnWG, Linky (RJ12); MODBUS TCP (RJ45)
Mountingwall-mounted, on backplate
CertificationsCE, UKCA, EV READY, MID, Eichrecht

Part numbers

Show all part numbers (11)

CP840-LTE-ETH-16A3-MID, CP830-LTE-ETH-16A3-L7.5-MID, CP830-LTE-ETH-16A3-L5-MID, CP810-LTE-ETH-16A3-MID, CP840-LTE-ETH-32A1-MID, CP830-LTE-ETH-32A1-L7.5-MID, CP830-LTE-ETH-32A1-L5-MID, CP810-LTE-ETH-32A1-MID, CP810B-LTE-ETH-16A3-MID-MTR, CP830B-LTE-ETH-16A3-L7.5MID-MTR, CP830B-LTE-ETH-16A3-L5-MIDMTR

Request a price and lead time

Flex Plus AC Station for Electric Vehicles, 7.4/11 kW, Type 2. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

What is the difference between CP810, CP830 and CP840?

The CP810 has a Type 2 socket, the CP840 a Type 2 socket with a shutter, and the CP830 a permanently attached Type 2 cable in 5 metre or 7.5 metre lengths.

Can the station be connected to a single-phase supply?

Yes. The 32A1 versions run on 230 V at 32 A and deliver as much as 7.4 kW, while the 16A3 versions are three-phase at 400 V and deliver up to 11 kW.

Which models have a display and Eichrecht certification?

The three-phase CP810B and CP830B models with the MTR suffix have a display measuring 3.5 inches with capacitive buttons and Eichrecht certification.