International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Sweepolet® Contoured Integrally Reinforced Branch Outlet, 1/8 up to 36 NPS

Sweepolet® is a forged outlet shaped to the run pipe and integrally reinforced, so a branch can be butt-welded in with low stress concentration. That low stress intensification factor gives long fatigue life on lines that see cycling.

Type
contoured, integrally reinforced branch outlet
Size
1/8 NPS – 36 NPS
Wall schedules
5S, 10S, STD, XS, XXS, S160
Design
ASME Section III, ASME B31.1, ASME B31.3, MSS SP-97

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Pressure pulsation, thermal cycling and vibration all concentrate stress at a branch connection, and that is where fatigue cracks tend to start. Sweepolet® addresses this with a contoured body that follows the curve of the run pipe and blends smoothly into the branch, with the reinforcement forged in. The resulting low stress intensification factor keeps local stresses down and extends fatigue life.

Inspection is straightforward. The attachment weld can be examined by radiography, ultrasonic testing and other standard non-destructive methods, which matters on systems where every weld has to be proven. Reinforcement is matched to the requirements of each connection.

The outlet is made as a butt-weld branch connector, with ends prepared per ASME B16.25, and as a socket-weld version. Sizes run from 1/8 up to 36 NPS, in 5S, 10S, STD, XS, XXS and S160 wall schedules. Design checks are made to MSS SP-97, read with ASME Section III, ASME B31.1 and ASME B31.3; MSS SP-97 also sets the face-to-pipe dimension, and marking is per MSS SP-25.

To select a part, give run and branch sizes and wall thicknesses, material and end type. Dimensions are in the manufacturer's catalogue, and 3D CAD models are available.

Technical specifications

Typecontoured, integrally reinforced branch outlet
Size1/8 NPS – 36 NPS
Wall schedules5S, 10S, STD, XS, XXS, S160
DesignASME Section III, ASME B31.1, ASME B31.3, MSS SP-97
MarkingMSS SP-25
Face to pipeMSS SP-97
Butt-weld endsASME B16.25
Versionsbutt weld, socket weld

Request a price and lead time

Sweepolet® Contoured Integrally Reinforced Branch Outlet, 1/8 up to 36 NPS. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Why choose Sweepolet® over a plain branch weld?

Its contoured shape and built-in reinforcement give a low stress intensification factor, so the joint lasts longer under cyclic loading.

Can the weld be checked by NDT?

Yes, the attachment weld is easily examined by radiography, ultrasonic testing and other standard methods.

What size range is available?

From 1/8 up to 36 NPS, in 5S, 10S, STD, XS, XXS and S160 wall schedules.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides