71000 Series Streamlined Angle Control Valve for Coker and Visbreaker Duty, 25–300 mm
A single-seated angle valve with a swept body and a heavily top-guided plug, meant for hydrocarbon lines where heat, big pressure drops, coking and flashing liquids quickly ruin ordinary globe trim. It is most often found on visbreakers, delayed cokers, flexi-cokers and gasifiers.
- Body type
- streamlined angle, single seat
- Sizes
- 25–300 mm (1–12 in)
- Ratings, flanges
- ANSI 150–2500; JIS 10K–63K; PN 10–400
- Body materials
- WCC, LCC, WC9, 316 and 347 stainless
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Inside the body there are no dead pockets for the flow to swirl in. The contours are swept so that eddies and flow reversal are avoided, and the walls see far less erosion. The contoured equal-percentage plug seats downwards on a threaded seat ring; together they shape a venturi outlet that shields the downstream area. The plug seating face is cut at 30 degrees and the seat ring at 40 degrees, and the plug surface is hardened.
On visbreaker furnaces the quench design earns its place. Gas oil is fed through the bonnet flange and passes into the plug via holes or grooves, cooling the process stream before it leaves the valve. That keeps hard coke from building up, which is the usual reason plugs bind. A flushing connection can be specified for fluids carrying solids or for very hot refinery service, and on high-pressure duty an equalising connection offsets the out-of-balance force of the single-seat layout.
Bodies are cast in WCC carbon steel, LCC low-carbon steel, WC9 chrome-moly, or 316 and 347 stainless. Flanged ends follow ANSI 150–2500, JIS 10K–63K or PN 10–400, in sizes from 25 mm to 300 mm (1 in to 12 in). A standard bolted bonnet with PTFE-based packing covers −46 °C to +343 °C; the extension bonnet with graphite packing raises the limit to +566 °C. Low-E low-emission packing is offered too. Rangeability is 50:1, and shut-off meets Class IV as standard or Class V with high-thrust actuation.
Besides coking units, the series handles pressure and level control loops, emergency blowdown and dropout service, crude upgraders processing bitumen from tar sands, and sour service. Flow-to-open and flow-to-close versions are built.
Actuation is by a Model 87/88 multi-spring diaphragm or a 51/52/53 piston cylinder. Materials and design reference NACE MR0175/ISO 15156-1 and MR0103, ISO 15848 Class A and IEC 60534-4.
Technical specifications
| Body type | streamlined angle, single seat |
|---|---|
| Sizes | 25–300 mm (1–12 in) |
| Ratings, flanges | ANSI 150–2500; JIS 10K–63K; PN 10–400 |
| Body materials | WCC, LCC, WC9, 316 and 347 stainless |
| Characteristic | equal percentage |
| Rangeability | 50:1 |
| Seat leakage | Class IV (standard); Class V (high-thrust actuation) |
| Temperature | −46 to +343 °C (standard bonnet, PTFE); −46 to +566 °C (extension bonnet, graphite) |
| Flow direction | flow-to-open / flow-to-close |
| Actuator | 87/88 spring diaphragm; 51/52/53 piston cylinder |
| Packing | PTFE, graphite, Low-E |
| Standards | NACE MR0175/ISO 15156-1, MR0103, ISO 15848 Class A, IEC 60534-4 |
Request a price and lead time
71000 Series Streamlined Angle Control Valve for Coker and Visbreaker Duty, 25–300 mm. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What temperature range does the valve cover?
From −46 °C to +343 °C with the standard bonnet and PTFE-based packing, and up to +566 °C with the extension bonnet and graphite packing.
Which end connections can be ordered?
Flanged ends to ANSI 150–2500, JIS 10K–63K or PN 10–400, in sizes 25–300 mm.
Is it suitable for sour hydrocarbon service?
Yes, materials can be supplied to NACE MR0175/ISO 15156-1 and MR0103.