International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

TTVA 2000 kVA dry cast-resin transformer, 15.75/0.42 kV

The TTVA 2000 kVA is a dry resin distribution transformer built with vacuum technology. Primary voltage is 15.75 kV and secondary voltage 0.42 kV. It steps down the distribution network voltage for industrial, municipal and individual consumers.

Type
Dry resin distribution transformer
Series
TTVA
Technology
Dry, vacuum
Rated power
2000 kVA

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The TTVA 2000 kVA belongs to the dry resin transformers made with vacuum technology. It is used in power networks as a standard distribution transformer. The primary voltage is 15.75 kV and the secondary voltage is 0.42 kV. Ratings and voltages of the other versions in the TTVA series are given in the name of each model.

A distribution transformer lowers the voltage of the current flowing in the distribution network. The prevailing network voltage is 15 kV, with 6 kV, 10 kV and 21 kV found in small areas. The lowered voltage is 0.4 kV or another value, generally below 1 kV.

The unit is suited to supplying end devices: industrial loads, municipal and residential consumers, and individual consumers.

Industrial plants that have their own medium voltage lines can install distribution transformers as well. The same applies where such lines run nearby, provided additional supply points for the plant's low voltage network can be taken from them.

Industrial low voltage networks are mostly supplied at 0.4 kV. There are exceptions where the voltage of the end network is higher than 0.4 kV, for example 0.66 kV. The secondary voltage of 0.42 kV should be matched to the consumer's network before a model is chosen.

Technical specifications

TypeDry resin distribution transformer
SeriesTTVA
TechnologyDry, vacuum
Rated power2000 kVA
Primary voltage15.75 kV
Secondary voltage0.42 kV
Prevailing network voltage15 kV (6 kV, 10 kV, 21 kV in small areas)
Lowered network voltage0.4 kV or other, generally below 1 kV

How it compares with similar models

ParameterTTVA 2000 kVA dry cast-resin transformer, 15.75/0.42 kVTTVA 1000 kVA dry cast-resin transformer, 15.75/0.42 kVTTVA 2500 kVA dry cast-resin transformer, 15.75/0.42 kVTTVA 1250 kVA dry cast-resin transformer, 15.75/0.4 kV
Rated power2000 kVA1000 kVA2500 kVA1250 kVA
Secondary voltage0.42 kV0.42 kV0.42 kV0.4 kV

Request a price and lead time

TTVA 2000 kVA dry cast-resin transformer, 15.75/0.42 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which networks is the TTVA transformer intended for?

Distribution networks, where it steps the voltage down. The prevailing network voltage is 15 kV, with 6 kV, 10 kV or 21 kV in small areas.

What is the secondary voltage of this model?

The 2000 kVA model has a secondary voltage of 0.42 kV. Industrial low voltage networks are most often supplied at 0.4 kV, and 0.66 kV also occurs.

Can a company install this transformer on its own network?

Yes, if the company has its own medium voltage lines, or such lines run nearby and additional supply points for the plant's low voltage network can be taken from them.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides