TTVA 1250 kVA dry cast-resin transformer, 15.75/0.4 kV
The TTVA 1250 kVA is a dry resin distribution transformer built with vacuum technology. Primary voltage is 15.75 kV and secondary voltage 0.4 kV. It steps down the distribution network voltage for industrial, municipal and individual consumers.
- Type
- Dry resin distribution transformer
- Series
- TTVA
- Technology
- Dry, vacuum
- Rated power
- 1250 kVA
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The TTVA 1250 kVA belongs to the dry resin transformers made with vacuum technology. It is used in power networks as a standard distribution transformer. The primary voltage is 15.75 kV and the secondary voltage is 0.4 kV. Ratings and voltages of the other versions in the TTVA series are given in the name of each model.
A distribution transformer lowers the voltage of the current flowing in the distribution network. The prevailing network voltage is 15 kV, with 6 kV, 10 kV and 21 kV found in small areas. The lowered voltage is 0.4 kV or another value, generally below 1 kV.
The unit is suited to supplying end devices: industrial loads, municipal and residential consumers, and individual consumers.
Industrial plants that have their own medium voltage lines can install distribution transformers as well. The same applies where such lines run nearby, provided additional supply points for the plant's low voltage network can be taken from them.
Industrial low voltage networks are mostly supplied at 0.4 kV. There are exceptions where the voltage of the end network is higher than 0.4 kV, for example 0.66 kV. The secondary voltage of 0.4 kV should be matched to the consumer's network before a model is chosen.
Technical specifications
| Type | Dry resin distribution transformer |
|---|---|
| Series | TTVA |
| Technology | Dry, vacuum |
| Rated power | 1250 kVA |
| Primary voltage | 15.75 kV |
| Secondary voltage | 0.4 kV |
| Prevailing network voltage | 15 kV (6 kV, 10 kV, 21 kV in small areas) |
| Lowered network voltage | 0.4 kV or other, generally below 1 kV |
How it compares with similar models
| Parameter | TTVA 1250 kVA dry cast-resin transformer, 15.75/0.4 kV | TTVA 1600 kVA dry cast-resin transformer, 15.75/0.4 kV | TTVA 1000 kVA dry cast-resin transformer, 15.75/0.42 kV | TTVA 2000 kVA dry cast-resin transformer, 15.75/0.42 kV |
|---|---|---|---|---|
| Rated power | 1250 kVA | 1600 kVA | 1000 kVA | 2000 kVA |
| Secondary voltage | 0.4 kV | 0.4 kV | 0.42 kV | 0.42 kV |
Request a price and lead time
TTVA 1250 kVA dry cast-resin transformer, 15.75/0.4 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which networks is the TTVA transformer intended for?
Distribution networks, where it steps the voltage down. The prevailing network voltage is 15 kV, with 6 kV, 10 kV or 21 kV in small areas.
What is the secondary voltage of this model?
The 1250 kVA model has a secondary voltage of 0.4 kV. Industrial low voltage networks are most often supplied at 0.4 kV, and 0.66 kV also occurs.
Can a company install this transformer on its own network?
Yes, if the company has its own medium voltage lines, or such lines run nearby and additional supply points for the plant's low voltage network can be taken from them.