TTO Oil-Filled Distribution Transformer, 100 kVA – 7 MVA, up to 36 kV
The TTO is an oil-filled distribution transformer that steps medium voltage down to low voltage, or the reverse. It is rated 100 kVA – 7 MVA with MV up to 36 kV, ONAN or KNAN cooling and Dyn5 or Dyn11 vector groups.
- Rated power
- 100 kVA – 7 MVA
- Rated MV voltage
- up to 36 kV
- Rated LV voltage
- 400 V, 440 V, 800 (other ratio possible)
- Cooling
- ONAN or KNAN
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The TTO oil-filled transformer is used for the transmission and distribution of electrical energy. It converts medium voltage (MV) to low voltage (LV), or the reverse, so that power reaches end users. Oil-filled units are chosen where reliable operation and resistance to mechanical damage are required. The design gives very good cooling conditions, and because of the oil these transformers are comparatively small next to dry-type units of the same power.
Rated power is 100 kVA – 7 MVA and rated MV voltage is up to 36 kV. Rated LV voltage is 400 V, 440 V or 800, and another ratio can be made. Cooling is ONAN or KNAN and the insulation class follows N-EN 60085. Vector groups are Dyn5 and Dyn11, with other groups possible. Frequency is 50 or 60 Hz, maximum altitude is 1000 m above sea level and ambient temperature is -25 to 40 °C.
The core is cold-rolled transformer steel with inorganic insulation. Windings are round or profiled wire with class H insulation, in copper or aluminium. The tank is either hermetic, with no conservator, or fitted with a conservator, and is made of powder-painted sheet steel with a C4 or C5 anticorrosion system in RAL 7033. It stands on a wheeled chassis whose wheels can be reset to the direction of travel.
Standard fittings are porcelain HV bushings to DIN 42531 or EN 50180:2010 (or connector bushings), porcelain LV bushings to DIN 42531 or EN 50180:2010, an integrated gas, temperature and pressure protection device, a drain valve to EN 50216-4 or DIN 42551, earthing terminals on the chassis, rating plate, contact thermometer, oil filler on the cover, lifting lugs and an off-circuit tap changer.
Oil-filled transformers with an on-load tap changer are also built, in the conservator version. The full power range is available with a radiator tank. Options include a 7-position off-circuit tap changer (other adjustment on request), surge arresters and anti-vibration pads. Manufacture, testing and tolerances follow PN EN 60076-1 and PN EN 60076-6.
Technical specifications
| Rated power | 100 kVA – 7 MVA |
|---|---|
| Rated MV voltage | up to 36 kV |
| Rated LV voltage | 400 V, 440 V, 800 (other ratio possible) |
| Cooling | ONAN or KNAN |
| Insulation class | according to N-EN 60085 |
| Vector group | Dyn5, Dyn11 (other group possible) |
| Max. operating altitude | 1000 m above sea level |
| Ambient temperature range | -25 to 40 °C |
| Rated frequency | 50 or 60 Hz |
| Core | cold-rolled transformer steel with inorganic insulation |
| Windings | round or profiled wire with class H insulation, copper or aluminium |
| Tank | hermetic or with conservator, powder-painted, C4 or C5 anticorrosion system |
| Finish colour | RAL 7033 |
Request a price and lead time
TTO Oil-Filled Distribution Transformer, 100 kVA – 7 MVA, up to 36 kV. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
What power and voltage range does the TTO cover?
Rated power is 100 kVA – 7 MVA, MV is up to 36 kV and LV is 400 V, 440 V or 800. A different ratio can be made.
Which vector groups are available?
Dyn5 and Dyn11. Another connection group can be made by agreement.
Is an on-load tap changer version available?
Yes, oil-filled transformers with an on-load tap changer are built in the conservator version. The standard set includes an off-circuit tap changer.