SLIM — compact distribution transformer with class K fluid

SLIM is a compact distribution transformer up to 30 MVA for voltages up to 72 kV, insulated with class K fluid. It has smaller dimensions and weight and is designed for significant overloads.

Voltage
up to 72 kV
Power
up to 30 MVA
Standards
EN 50708, IEC, ANSI; Eco and ATEX versions
Insulation
non-flammable class K fluid

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Class K dielectric fluid has a high fire point, so using SLIM improves the fire safety of the installation. The transformer is built to EN 50708, IEC and ANSI, and Eco and ATEX versions are available. The reduced dimensions make it easier to place the unit in confined rooms and compact substations.

Technical specifications

Voltageup to 72 kV
Powerup to 30 MVA
StandardsEN 50708, IEC, ANSI; Eco and ATEX versions
Insulationnon-flammable class K fluid
Featuresreduced dimensions and weight, high overload capability

Replacement for

ТМГ-250/10, ТМГ-400/10, ТМГ-630/10, ТМГ-1000/10, ТМГ-1600/10, ТМГ-2500/10; ТМ-…/10, ТМЗ-…/10; ТМГ-…/35, ТМ-1000/35…ТМ-2500/35, ТМН-4000/35, ТМН-6300/35; there is no series analogue for class K fluid

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

SLIM — compact distribution transformer with class K fluid. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 23 00 00
HS, 6 digits8504 22
CN (EU)8504 23 00
HTSUS (USA)8504 23 00 41
China customs tariff8504 23 11 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

How does SLIM differ from a conventional oil-immersed transformer?

SLIM is smaller in size and weight, withstands significant overloads and is filled with class K fluid, which has a high fire point.

What are the rating and voltage of SLIM?

The transformer is made with ratings up to 30 MVA for voltages up to 72 kV.

What standards is SLIM built to?

EN 50708, IEC and ANSI, including Eco and ATEX versions.