Peritus OLTC Transformer (POT) distribution transformer with OLTC
Peritus OLTC Transformer (POT) is a distribution transformer with an on-load voltage regulation device. It is intended for networks with a high share of PV and wind plants, EV charging stations and storage systems, where the LV side voltage fluctuates noticeably.
- Regulation
- OLTC with small steps, automatic based on secondary voltage measurement
- Insulating fluid
- including vegetable esters
- Communication
- IEC 60870-5-101/104, DNP3, IEC 61850, SCADA integration
- Maintenance
- not required
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The OLTC switches taps in small steps, and control is automatic based on secondary voltage measurement, without switching the transformer off. Among the insulating fluid options are vegetable esters. For remote control the protocols IEC 60870-5-101/104, DNP3 and IEC 61850 are provided, so it integrates into the SCADA of the network company. According to the manufacturer, no maintenance is required. The dimensions are close to those of a standard distribution transformer.
Technical specifications
| Regulation | OLTC with small steps, automatic based on secondary voltage measurement |
|---|---|
| Insulating fluid | including vegetable esters |
| Communication | IEC 60870-5-101/104, DNP3, IEC 61850, SCADA integration |
| Maintenance | not required |
| Dimensions | close to a standard distribution transformer |
Replacement for
ТМГ-250/10…ТМГ-2500/10 (with off-circuit tap changer); with OLTC — ТМН-…/35; no direct analog for a 10/0.4 kV distribution transformer with OLTC
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
Peritus OLTC Transformer (POT) distribution transformer with OLTC. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8504 21 00 00 8504 22 10 00 8504 22 90 00 8504 23 00 00 |
|---|---|
| HS, 6 digits | 8504 21 |
| CN (EU) | 8504 21 00 8504 22 10 8504 22 90 8504 23 00 |
| HTSUS (USA) | 8504 21 00 20 8504 21 00 40 8504 21 00 60 8504 21 00 80 8504 22 00 40 8504 22 00 80 8504 23 00 41 8504 23 00 45 8504 23 00 80 |
| China customs tariff | 8504 21 00 00 8504 22 00 00 8504 23 11 00 8504 23 12 00 8504 23 13 00 8504 23 21 00 8504 23 29 00 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
How is voltage regulated in the POT?
The built-in OLTC switches taps in small steps under load. Control is automatic, based on the measured secondary voltage.
Which communication protocols does the transformer support?
IEC 60870-5-101/104, DNP3 and IEC 61850, with integration into SCADA provided.
Which networks is the POT intended for?
Distribution networks with a high share of PV and wind plants, EV charging stations and storage systems.