Minera oil-immersed distribution transformers up to 3.15 MVA, 36 kV

Minera is a series of oil-immersed transformers for distribution networks rated 50–3150 kVA. The voltage is 20 kV (24 kV class) or 35 kV (36 kV class) to 400 V. They are made in ground-mounted and pole-mounted versions.

Power
50–3150 kVA
Voltage
20 kV (24 kV class) or 35 kV (36 kV class) / 400 V
Insulation
oil
Cooling
ONAN, hermetically sealed completely filled tank

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The tank is hermetically sealed and completely filled, with ONAN cooling, so the oil does not contact the air and needs no conservator. Mineral oil to IEC 60296 is used. Complies with EN 50588-1 and EN 60076-1, with Ecodesign 548/2014 losses in classes A0Ak, A0Bk and A0Ck. Pole-mounted units go on overhead line poles, ground-mounted ones in packaged substations.

Technical specifications

Power50–3150 kVA
Voltage20 kV (24 kV class) or 35 kV (36 kV class) / 400 V
Insulationoil
CoolingONAN, hermetically sealed completely filled tank
Oilmineral oil to IEC 60296
StandardsEN 50588-1, EN 60076-1, Ecodesign 548/2014 (A0Ak, A0Bk, A0Ck)

Replacement for

ТМГ-250/10, ТМГ-400/10, ТМГ-630/10, ТМГ-1000/10, ТМГ-1600/10, ТМГ-2500/10; ТМ-…/10, ТМЗ-…/10; ТМГ-…/20; ТМГ-…/35

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

Minera oil-immersed distribution transformers up to 3.15 MVA, 36 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 21 00 00
8504 22 10 00
8504 22 90 00
HS, 6 digits8504 22
CN (EU)8504 21 00
8504 22 10
8504 22 90
HTSUS (USA)8504 21 00 20
8504 21 00 40
8504 21 00 60
8504 21 00 80
8504 22 00 40
8504 22 00 80
China customs tariff8504 21 00 00
8504 22 00 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What voltages are Minera transformers made for?

20 kV (24 kV class) or 35 kV (36 kV class), with LV of 400 V.

What is the power range?

From 50 to 3150 kVA, in ground-mounted and pole-mounted versions.

What Ecodesign classes do the losses meet?

Ecodesign 548/2014 in classes A0Ak, A0Bk and A0Ck, as well as EN 50588-1.