International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

I-Trafo regulated distribution transformer with ECOTAP VPD

i-Trafo is a distribution transformer with a built-in ECOTAP VPD OLTC. It automatically keeps the voltage stable in the distribution network when the MV voltage, the load or the generation on the LV side change.

Regulation
under load, ECOTAP VPD system
Purpose
compensation of MV voltage fluctuations and of load/generation changes on the LV side

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The ECOTAP VPD device is made by a specialist tap changer manufacturer, and the steps are switched under load, without de-energising. A conventional non-regulated transformer has to be switched off and re-tapped manually to change the tap. In the i-Trafo this operation is performed automatically. The regulation compensates MV voltage fluctuations and changes of load or generation on the LV side, so the transformer is installed in substations where the LV network has own sources or loads with a sharp profile.

Technical specifications

Regulationunder load, ECOTAP VPD system
Purposecompensation of MV voltage fluctuations and of load/generation changes on the LV side

Replacement for

ТМГ-250/10…ТМГ-2500/10 (with off-circuit tap changer); with OLTC — ТМН-…/35; no direct analog for a 10/0.4 kV distribution transformer with OLTC

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

I-Trafo regulated distribution transformer with ECOTAP VPD. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 21 00 00
8504 22 10 00
8504 22 90 00
8504 23 00 00
HS, 6 digits8504 21
CN (EU)8504 21 00
8504 22 10
8504 22 90
8504 23 00
HTSUS (USA)8504 21 00 20
8504 21 00 40
8504 21 00 60
8504 21 00 80
8504 22 00 40
8504 22 00 80
8504 23 00 41
8504 23 00 45
8504 23 00 80
China customs tariff8504 21 00 00
8504 22 00 00
8504 23 11 00
8504 23 12 00
8504 23 13 00
8504 23 21 00
8504 23 29 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Which OLTC device is installed in the i-Trafo?

ECOTAP VPD, made by a specialist tap changer manufacturer, which switches the steps under load.

Which fluctuations does the transformer compensate?

Voltage fluctuations on the MV side, as well as changes of load and generation on the LV side.

How does the i-Trafo differ from a non-regulated transformer?

A non-regulated transformer is switched off and re-tapped manually to change the tap. In the i-Trafo the steps change automatically without switching off.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides