I-Trafo regulated distribution transformer with ECOTAP VPD
i-Trafo is a distribution transformer with a built-in ECOTAP VPD OLTC. It automatically keeps the voltage stable in the distribution network when the MV voltage, the load or the generation on the LV side change.
- Regulation
- under load, ECOTAP VPD system
- Purpose
- compensation of MV voltage fluctuations and of load/generation changes on the LV side
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The ECOTAP VPD device is made by a specialist tap changer manufacturer, and the steps are switched under load, without de-energising. A conventional non-regulated transformer has to be switched off and re-tapped manually to change the tap. In the i-Trafo this operation is performed automatically. The regulation compensates MV voltage fluctuations and changes of load or generation on the LV side, so the transformer is installed in substations where the LV network has own sources or loads with a sharp profile.
Technical specifications
| Regulation | under load, ECOTAP VPD system |
|---|---|
| Purpose | compensation of MV voltage fluctuations and of load/generation changes on the LV side |
Replacement for
ТМГ-250/10…ТМГ-2500/10 (with off-circuit tap changer); with OLTC — ТМН-…/35; no direct analog for a 10/0.4 kV distribution transformer with OLTC
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
I-Trafo regulated distribution transformer with ECOTAP VPD. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8504 21 00 00 8504 22 10 00 8504 22 90 00 8504 23 00 00 |
|---|---|
| HS, 6 digits | 8504 21 |
| CN (EU) | 8504 21 00 8504 22 10 8504 22 90 8504 23 00 |
| HTSUS (USA) | 8504 21 00 20 8504 21 00 40 8504 21 00 60 8504 21 00 80 8504 22 00 40 8504 22 00 80 8504 23 00 41 8504 23 00 45 8504 23 00 80 |
| China customs tariff | 8504 21 00 00 8504 22 00 00 8504 23 11 00 8504 23 12 00 8504 23 13 00 8504 23 21 00 8504 23 29 00 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
Which OLTC device is installed in the i-Trafo?
ECOTAP VPD, made by a specialist tap changer manufacturer, which switches the steps under load.
Which fluctuations does the transformer compensate?
Voltage fluctuations on the MV side, as well as changes of load and generation on the LV side.
How does the i-Trafo differ from a non-regulated transformer?
A non-regulated transformer is switched off and re-tapped manually to change the tap. In the i-Trafo the steps change automatically without switching off.