Distribution transformers, including amorphous-core types, and medium-rated transformers
Distribution transformers for the networks of grid companies, industrial and commercial sites and solar power plants. The range covers medium- and low-rated transformers, models with an amorphous steel magnetic core, single-phase pole-mounted, pad-mounted and solar inverter transformers. The design is defined by the customer specification under IEEE and IEC standards.
- Range
- medium- and low-rated transformers; amorphous-core; single-phase pole-mounted; single- and three-phase pad-mounted; for solar inverters
- Standards
- IEEE, IEC
- Design
- per customer specification
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The manufacturer positions itself as one of the leading suppliers of energy-efficient distribution transformers with an amorphous steel magnetic core. Such a core has reduced no-load losses. The magnetic core is wound from thin amorphous ribbon, which is remagnetized with lower losses than ordinary electrical steel. A distribution transformer is energized around the clock, so the reduction of these losses is noticeable in the annual balance of the network.
Medium- and low-rated power transformers work at distribution network substations of 6-35 kV and at industrial sites. The same medium-rated models are used for commercial buildings. Single-phase pole-mounted transformers are installed on overhead line poles and serve extensive overhead networks where transformation is close to the consumer. Such machines are typical for rural and suburban networks. Single- and three-phase pad-mounted models have an enclosed housing for outdoor installation and are intended for cable networks, including residential areas. The housing is set on a ground-level foundation, cables enter from below, and live parts are closed to access.
A separate line is transformers for solar inverters (inverter duty). They step up the voltage of the inverters of a photovoltaic plant and connect the plant to the medium-voltage grid. The load of such a transformer changes with solar generation during the day. The transformer is selected for the inverter rating and output voltage, and these data are given in the inquiry.
The transformers are made with proven technologies from high-quality materials, and quality control is carried out at all production stages. The design is agreed with the customer specification in full compliance with the international IEEE and IEC standards. This way one manufacturer covers orders for networks built to American and to international norms. The manufacturer does not state specific rated powers and voltages on the product page, they are defined by the order, so the parameters are fixed in the technical specification. The inquiry should state the rating, primary and secondary voltage, winding connection and installation type.
Transformers, GIS and surge arresters are built at the Hamakawasaki plant in Kawasaki, transformers also at the Mie plant, and the high-voltage test laboratories are JAB accredited. The company has experience of complex supplies and since 1978 has completed over 100 turnkey substations abroad with voltages up to 800 kV.
Technical specifications
| Range | medium- and low-rated transformers; amorphous-core; single-phase pole-mounted; single- and three-phase pad-mounted; for solar inverters |
|---|---|
| Standards | IEEE, IEC |
| Design | per customer specification |
Replacement for
ТМГ-250/10, ТМГ-400/10, ТМГ-630/10, ТМГ-1000/10, ТМГ-1600/10, ТМГ-2500/10; ТМ-…/10, ТМЗ-…/10; ТД-10000/35, ТДНС-10000/35, ТДНС-16000/35; no amorphous-core units in series production
selected by purpose and main parameters, please confirm with our manager
Request a price and lead time
Distribution transformers, including amorphous-core types, and medium-rated transformers. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8504 21 00 00 8504 22 10 00 8504 22 90 00 8504 33 00 00 8504 34 00 00 |
|---|---|
| HS, 6 digits | 8504 21 8504 22 |
| CN (EU) | 8504 21 00 8504 22 10 8504 22 90 8504 33 00 8504 34 00 |
| HTSUS (USA) | 8504 21 00 00 8504 22 00 40 8504 33 00 00 8504 34 00 00 |
| China customs tariff | 8504 21 00 00 8504 22 00 00 8504 33 00 00 8504 34 00 00 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
Which types of distribution transformers are built?
Medium- and low-rated transformers, models with an amorphous core, single-phase pole-mounted, single- and three-phase pad-mounted and solar inverter transformers.
To which standards are these transformers built?
To the international IEEE and IEC standards, with the design agreed with the customer specification.
For which networks and sites are these transformers suitable?
For 6-35 kV distribution networks, industrial and commercial sites, cable networks of residential areas and solar power plants.