СУЗД-01...06 motor protection and control station on microprocessor relays, up to 1000 A
СУЗД-01...06 controls an electric motor and protects it with microprocessor motor protection relays РДЦ-01...06. Rated currents are up to 1000 A, there are four control modes and digital and light indication. Versions are available with reverse, backup supply and star-delta starting.
- Type
- Motor control and protection station on microprocessor relays
- Motor protection relays
- РДЦ-01...06
- Rated currents
- 1000 A
- Control modes
- Manual, automatic, remote, telecontrol
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
The СУЗД-01...06 stations control a motor and protect it by means of microprocessor motor protection relays РДЦ-01...06. Rated current of the station is up to 1000 A. The protection functions depend on which relay of the РДЦ-01...06 range is fitted in a given station.
Feeders are operated in four modes: manual, automatic, remote and telecontrol. Monitored parameters are shown by digital and light indication. An RS-485 interface is provided for data exchange.
Four versions are offered. СУЗД-01...06 is the base control and protection station on microprocessor relays. СУЗД-01...06Р runs the motor in reverse. СУЗД-01...06А is supplied from a backup mains. СУЗД-01...06 з/т starts the motor with a star-delta scheme.
Within the СУЗД series these stations sit alongside the versions on simple relays. Where overcurrent and thermal protection are enough, there are СУЗД-Т and СУЗД-ТЕ, and stations with a regulated soft start are designated СУЗД-П. The СУЗД-П01...06 version is also built on microprocessor relays.
The versions differ in their extra options: reverse, backup supply or star-delta starting. The control modes and indication are described for the station as a whole. СУЗД-05 is one example of a version from this series. The station is chosen by the required protection relay from the РДЦ-01...06 range and by the required version.
Technical specifications
| Type | Motor control and protection station on microprocessor relays |
|---|---|
| Motor protection relays | РДЦ-01...06 |
| Rated currents | 1000 A |
| Control modes | Manual, automatic, remote, telecontrol |
| Indication | Digital and light |
| Interface | RS-485 |
| Versions | СУЗД-01...06, СУЗД-01...06Р, СУЗД-01...06А, СУЗД-01...06 з/т |
| Motor reverse operation | СУЗД-01...06Р |
| Backup mains supply | СУЗД-01...06А |
| Star-delta starting | СУЗД-01...06 з/т |
How it compares with similar models
| Parameter | СУЗД-01...06 motor protection and control station on microprocessor relays, up to 1000 A | СУЗД-М motor control station on an industrial controller, with АСУ ТП integration | СУЗД-Ч motor control and protection station with a frequency converter, 0.25 to 630 kW | СУЗД-П motor protection and control station with soft starter, 0.25 to 630 kW |
|---|---|---|---|---|
| Type | Motor control and protection station on microprocessor relays | Motor control and protection station on an industrial controller | Motor control and protection station with a frequency converter | Motor protection and control station with soft starter |
| Control modes | Manual, automatic, remote, telecontrol | four: manual, automatic, remote, telecontrol | two: manual and automatic | Manual, automatic, remote, telecontrol |
| Indication | Digital and light | цифрова та світлова | цифрова та світлова | — |
| Versions | СУЗД-01...06, СУЗД-01...06Р, СУЗД-01...06А, СУЗД-01...06 з/т | СУЗД-М04(06), СУЗД-М04(06)Ч | СУЗД-Ч, СУЗД-Ч01...06 | — |
Request a price and lead time
СУЗД-01...06 motor protection and control station on microprocessor relays, up to 1000 A. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which protection relays are used in СУЗД-01...06?
РДЦ-01...06 microprocessor motor protection relays, and the set of protections depends on the relay fitted.
Which versions does the station come in?
The base СУЗД-01...06, СУЗД-01...06Р with reverse, СУЗД-01...06А with a backup mains supply and СУЗД-01...06 з/т with star-delta starting.
In which modes are feeders controlled?
In four modes: manual, automatic, remote and telecontrol.