СУЗД-01...06 motor protection and control station on microprocessor relays, up to 1000 A

СУЗД-01...06 controls an electric motor and protects it with microprocessor motor protection relays РДЦ-01...06. Rated currents are up to 1000 A, there are four control modes and digital and light indication. Versions are available with reverse, backup supply and star-delta starting.

Type
Motor control and protection station on microprocessor relays
Motor protection relays
РДЦ-01...06
Rated currents
1000 A
Control modes
Manual, automatic, remote, telecontrol

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The СУЗД-01...06 stations control a motor and protect it by means of microprocessor motor protection relays РДЦ-01...06. Rated current of the station is up to 1000 A. The protection functions depend on which relay of the РДЦ-01...06 range is fitted in a given station.

Feeders are operated in four modes: manual, automatic, remote and telecontrol. Monitored parameters are shown by digital and light indication. An RS-485 interface is provided for data exchange.

Four versions are offered. СУЗД-01...06 is the base control and protection station on microprocessor relays. СУЗД-01...06Р runs the motor in reverse. СУЗД-01...06А is supplied from a backup mains. СУЗД-01...06 з/т starts the motor with a star-delta scheme.

Within the СУЗД series these stations sit alongside the versions on simple relays. Where overcurrent and thermal protection are enough, there are СУЗД-Т and СУЗД-ТЕ, and stations with a regulated soft start are designated СУЗД-П. The СУЗД-П01...06 version is also built on microprocessor relays.

The versions differ in their extra options: reverse, backup supply or star-delta starting. The control modes and indication are described for the station as a whole. СУЗД-05 is one example of a version from this series. The station is chosen by the required protection relay from the РДЦ-01...06 range and by the required version.

Technical specifications

TypeMotor control and protection station on microprocessor relays
Motor protection relaysРДЦ-01...06
Rated currents1000 A
Control modesManual, automatic, remote, telecontrol
IndicationDigital and light
InterfaceRS-485
VersionsСУЗД-01...06, СУЗД-01...06Р, СУЗД-01...06А, СУЗД-01...06 з/т
Motor reverse operationСУЗД-01...06Р
Backup mains supplyСУЗД-01...06А
Star-delta startingСУЗД-01...06 з/т

How it compares with similar models

ParameterСУЗД-01...06 motor protection and control station on microprocessor relays, up to 1000 AСУЗД-М motor control station on an industrial controller, with АСУ ТП integrationСУЗД-Ч motor control and protection station with a frequency converter, 0.25 to 630 kWСУЗД-П motor protection and control station with soft starter, 0.25 to 630 kW
TypeMotor control and protection station on microprocessor relaysMotor control and protection station on an industrial controllerMotor control and protection station with a frequency converterMotor protection and control station with soft starter
Control modesManual, automatic, remote, telecontrolfour: manual, automatic, remote, telecontroltwo: manual and automaticManual, automatic, remote, telecontrol
IndicationDigital and lightцифрова та світловацифрова та світлова—
VersionsСУЗД-01...06, СУЗД-01...06Р, СУЗД-01...06А, СУЗД-01...06 з/тСУЗД-М04(06), СУЗД-М04(06)ЧСУЗД-Ч, СУЗД-Ч01...06—

Request a price and lead time

СУЗД-01...06 motor protection and control station on microprocessor relays, up to 1000 A. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which protection relays are used in СУЗД-01...06?

РДЦ-01...06 microprocessor motor protection relays, and the set of protections depends on the relay fitted.

Which versions does the station come in?

The base СУЗД-01...06, СУЗД-01...06Р with reverse, СУЗД-01...06А with a backup mains supply and СУЗД-01...06 з/т with star-delta starting.

In which modes are feeders controlled?

In four modes: manual, automatic, remote and telecontrol.