International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

SEL-547 — relay for distributed generation grid connection protection

A relay for the connection point of small and distributed generation to the network, with voltage and frequency protection and disconnection of the generator when a grid fault occurs. The model has been discontinued.

Designation
SEL-547
Status
discontinued; the manufacturer keeps support and warranty
Recommended replacement
SEL-751, SEL-849

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Product status

Status
discontinued; the manufacturer keeps support and warranty
Recommended replacement
SEL-751, SEL-849

Description

The SEL-547 is a relay for the point where small and distributed generation connects to the public network. Its task is to watch voltage and frequency at that connection and to separate the generator from the network when a disturbance appears on the grid side. Without such protection, a local generator could keep supplying an isolated part of the line, which creates risks for maintenance crews and for the equipment itself.

Voltage protection reacts to abnormal voltage levels that signal a problem in the network, while frequency protection responds when system frequency moves outside its permitted band. The two functions are normally used together, because each can recognise conditions the other may miss. When a limit stays exceeded for the set time, the relay opens the interconnection breaker so that the generator stops feeding the grid.

This relay suits connection points where a generator must leave the network quickly and reliably after a fault. The model has been discontinued, so new projects should not rely on it. The manufacturer recommends the SEL-751 or SEL-849 as replacements, and existing installations remain supported by the manufacturer.

Technical specifications

DesignationSEL-547
Statusdiscontinued; the manufacturer keeps support and warranty
Recommended replacementSEL-751, SEL-849

Request a price and lead time

SEL-547 — relay for distributed generation grid connection protection. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides