TC 1500 V central inverters with integrated 35 kV step-up substation (3.1–8.8 MW) for solar plants

TC series central inverters with an integrated 35 kV step-up substation have a power of 3.125 to 8.8 MW and operate from 1500 V arrays. They are installed at large solar plants on flat terrain, in deserts, in the Gobi and on difficult land. The unit is delivered assembled and tested, so there is less work on site.

Models
TC4400KT-AL/-CL (4.4 MW), TC3125KFT (3.125 MW), TC8800KT-EL (8.8 MW)
Max. input voltage
1500 V DC, MPPT 895–1500 V (full power 895–1300 V)
Efficiency (max.)
99.05% (TC4400), 99.11% (TC3125), 99.08% (TC8800)
Transformer
35 ±2×2.5% / 0.63 kV, Dy11, ONAN, uk 6.5–8%, HV compartment with vacuum circuit breaker

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

One unit combines a central inverter, a 35 kV step-up transformer and a high-voltage compartment with a vacuum circuit breaker. In European terminology this is an inverter-transformer station (MV skid). The built-in transformer is oil-filled, 35 ±2×2.5% / 0.63 kV, vector group Dy11, ONAN cooling, PCB-free mineral oil. The short-circuit voltage is 8% in the TC4400 with a tolerance of +10%. The AC-side breaking capacity is 65 kA.

TC4400KT-AL and TC4400KT-CL are rated for a nominal output power of 4400 kW. The maximum input voltage is 1500 V, the MPPT range is 895–1500 V, and full power is available at 895–1300 V. There are three MPPT trackers, 18–24 DC inputs for bifacial 182/210 modules, and a maximum input current of 5737 A. The maximum efficiency is 99.05%, and the China-weighted efficiency is 98.55%. The TC3125KFT of 3125 kW has an efficiency of 99.11% and a 3125 kVA transformer delivering up to 3438 kVA at 50 °C, a short-circuit voltage of 6.5%, dimensions of 5006 × 2900 × 2545 mm and a weight of 13 t. The international model TC8800KT-EL of 8.8 MW has an efficiency of 99.08%.

The current distortion factor is less than 3%, and the DC component is less than 0.5%. The power factor is 0.99 at rated load and is adjustable from 0.8 inductive to 0.8 capacitive. Harmonic suppression and adaptive matching to grid impedance keep operation at a short-circuit ratio of 1.0 (SCCR 0.7). An SVG function, fast active power response, PID protection options, an energy storage interface and an IEC 61850 adapter are available. Protections cover overvoltages, overcurrents and lightning on the AC and DC sides, and monitoring of the grid, earth faults, insulation and overheating.

The TC4400 unit has dimensions of 7464 × 2948 × 2610 mm and a weight of 16 t. The degree of protection is IP54, and IP55/IP65 for the inverter, with corrosion class C3 and C4/C5 options. The operating temperature is −35…+60 °C with derating above 40 °C, altitude up to 5000 m, and humidity 0–100% non-condensing. Communication is via RS-485 and Ethernet. The equipment complies with GB/T 37408, GB/T 19964, NB/T 32004, Q/GDW 1617 and other standards.

Technical specifications

ModelsTC4400KT-AL/-CL (4.4 MW), TC3125KFT (3.125 MW), TC8800KT-EL (8.8 MW)
Max. input voltage1500 V DC, MPPT 895–1500 V (full power 895–1300 V)
Efficiency (max.)99.05% (TC4400), 99.11% (TC3125), 99.08% (TC8800)
Transformer35 ±2×2.5% / 0.63 kV, Dy11, ONAN, uk 6.5–8%, HV compartment with vacuum circuit breaker
Power factor0.8 ind. … 0.8 cap.
Dimensions, weight (TC4400)7464×2948×2610 mm, 16 t
Conditions−35…+60 °C, up to 5000 m, IP54 (inverter IP55/IP65)
Gridoperation at SCR 1.0; SVG function at night; energy storage interface (options)

Request a price and lead time

TC 1500 V central inverters with integrated 35 kV step-up substation (3.1–8.8 MW) for solar plants. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 40 88 00
HS, 6 digits8504 40
CN (EU)8504 40 88
HTSUS (USA)8504 40 95 80
China customs tariff8504 40 30 90

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What power do TC series inverters have?

The TC3125KFT has 3125 kW, the TC4400KT-AL and TC4400KT-CL 4400 kW each, and the TC8800KT-EL 8.8 MW. The maximum input voltage is 1500 V.

What transformer is built into the unit?

An oil-filled transformer 35 ±2×2.5% / 0.63 kV, vector group Dy11, ONAN cooling. The short-circuit voltage is 8% in the TC4400 and 6.5% in the TC3125.

In what conditions can the TC4400 unit operate?

At temperatures from −35 to +60 °C, with derating above 40 °C, and at altitudes up to 5000 m. The degree of protection is IP54, and IP55 or IP65 for the inverter.