PCS-9567MV — integrated medium-voltage energy storage blocks (MV Skid), 2–10 MVA, 6.6–33 kV

NR PCS-9567MV are integrated medium-voltage blocks (MV Skid) rated 2000–10 000 kVA for connecting energy storage systems to 6.6–33 kV grids. A common frame in a container carries bidirectional 1500 V series PCS-9567 converters, a step-up oil-immersed transformer and an RMU. The block is assembled, configured and tested at the factory.

Versions
MV-3500 (2000–3500 kVA), MV-5000 (4000/5000 kVA), MV-7000 (5000–7000 kVA), MV-10000 (8000–10 000 kVA)
MV grid voltage
6.6–33 kV ±5 % (MV-3500/5000); 11–33 kV ±5 % (MV-7000/10000)
Composition
2 or 4 PCS-9567, oil-immersed transformer Dy11(-y11), RMU 12/24/36 kV 630 A
PCS efficiency
98.5–98.7 %

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The storage is connected on a plug-and-play principle. Factory readiness shortens construction time, the amount of work on site and the costs of unloading and transport.

The range has four sizes. The PCS-9567MV-3500 (2000–3500 kVA) and PCS-9567MV-5000 (4000 or 5000 kVA) each contain two converters in a 20-foot container weighing 19 and 24.3 t, with a 6.6–33 kV ±5 % grid. The PCS-9567MV-7000 (5000–7000 kVA) and PCS-9567MV-10000 (8000–10 000 kVA) each have four converters in a 40-foot container weighing 32.4 and 38.8 t, with an 11–33 kV ±5 % grid.

Converter efficiency is 98.5–98.7 %, the battery voltage range is 1050–1500 V, and full power is delivered at 1500 V. Operation is four-quadrant, the power factor is above 0.99, total harmonic distortion is below 3 %, and the frequency is 50/60 Hz. The transformer is oil-immersed with vector group Dy11, and for four converters with two low-voltage windings it is Dy11-y11. Cooling is ONAN or KNAN, with a temperature rise of 60 K for the oil and 65 K for the winding at 40 °C. The windings are aluminum or copper, the oil is mineral or natural ester, efficiency is per IEC or IEC Tier-2, and pressure, temperature and gas relays are fitted.

The RMU is made for 12, 24 or 36 kV and 630 A, with SF6 or non-SF6 insulation (up to 24 kV). Withstand is 20 kA/3 s, optionally 25 kA/3 s, with internal arc class IAC A FL 20 kA 1 s. On the DC side there are a disconnector and fuses, and on the AC side a motorized switch. Surge arresters of type II or I+II, insulation monitoring, smoke sensors and a 1 kVA UPS for 15 min are provided, optionally for 1 or 2 h.

The block operates at −35…+60 °C and at altitudes up to 5000 m, with ingress protection IP54 and anticorrosion versions from C4-H to C5-VH. For the grid it forms the voltage (grid forming), regulates reactive power and power factor, rides through voltage sags and surges (L/HVRT) and frequency deviations (L/HFRT), and has soft start and stop. Applications include energy time shifting, frequency regulation and peak load shaving. The manufacturer declares conformity with CE, VDE, ISO and EN.

Technical specifications

VersionsMV-3500 (2000–3500 kVA), MV-5000 (4000/5000 kVA), MV-7000 (5000–7000 kVA), MV-10000 (8000–10 000 kVA)
MV grid voltage6.6–33 kV ±5 % (MV-3500/5000); 11–33 kV ±5 % (MV-7000/10000)
Composition2 or 4 PCS-9567, oil-immersed transformer Dy11(-y11), RMU 12/24/36 kV 630 A
PCS efficiency98.5–98.7 %
TransformerONAN/KNAN, temperature rise 60 K (oil) / 65 K (winding), Al or Cu, mineral or ester oil
RMUSF6 or non-SF6 (≤24 kV), 20 kA/3 s (option 25 kA/3 s), IAC A FL 20 kA 1 s
Dimensions, weight20-foot container, 19–24.3 t; 40-foot container, 32.4–38.8 t
Conditions−35…+60 °C, up to 5000 m, IP54, corrosion class C4-H…C5-VH
Grid functionsgrid forming, L/HVRT, L/HFRT, Q and cos φ regulation
ConformityCE, VDE, ISO, EN

Request a price and lead time

PCS-9567MV — integrated medium-voltage energy storage blocks (MV Skid), 2–10 MVA, 6.6–33 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 40 88 00
HS, 6 digits8504 40
CN (EU)8504 40 88
HTSUS (USA)8504 40 95 80
China customs tariff8504 40 99 99

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What grid voltages is the PCS-9567MV designed for?

The MV-3500 and MV-5000 operate in 6.6–33 kV ±5 % grids. The MV-7000 and MV-10000 operate in 11–33 kV ±5 % grids.

What are the weight and size of the blocks?

Blocks with two converters are housed in a 20-foot container weighing 19 and 24.3 t. Blocks with four converters are housed in a 40-foot container weighing 32.4 and 38.8 t.

Does the block support grid forming mode?

Yes, it has grid forming, ride-through of sags and surges (L/HVRT) and of frequency deviations (L/HFRT). The power factor is above 0.99 and harmonics are below 3 %.