International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

SAI/SARI multi-turn actuators for nuclear plants (inside containment), 10–6400 Nm

SAI/SARI are multi-turn actuators for valve automation in nuclear power plants, used inside containment. They are qualified to IEEE 382-2006 and cover torques of 10 Nm to 6400 Nm.

Type
multi-turn actuators for nuclear power plants, inside containment
Duty
SAI: open-close and positioning; SARI: modulating
Torque range
10 Nm to 6400 Nm
Output speeds
4 1/min to 180 1/min

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Valves in nuclear power plants are automated by the SAI/SARI type range. The actuators are used inside containment and are qualified in compliance with IEEE 382-2006. DBE resistant SAI/SARI actuators can take over safety functions under DBE conditions. SAI multi-turn actuators serve open-close duty and positioning duty, while SARI actuators are designed for modulating duty.

Torque is 10 Nm to 6400 Nm and output speed is 4 1/min to 180 1/min. The actuator senses limits and torque, runs on 3-phase AC motors and has a handwheel for manual operation. Enclosure protection is IP68 and corrosion protection is KS.

The ambient temperature range is -30 °C to +80 °C. LOCA/DBE resistance is given as a short-time maximum of 220 °C at 6 bar (abs). Options are a mechanical position indicator, a stem protection tube and wet paint.

The design is light and compact with simple installation. Electrical connection uses the plug/socket connector (terminals as an option), cable entries come in different versions and valve attachments follow DIN and ISO standards.

Technical specifications

Typemulti-turn actuators for nuclear power plants, inside containment
DutySAI: open-close and positioning; SARI: modulating
Torque range10 Nm to 6400 Nm
Output speeds4 1/min to 180 1/min
Motors3-phase AC
Enclosure protectionIP68
Corrosion protectionKS
Ambient temperature-30 °C to +80 °C
LOCA/DBE resistancefor a short time max. 220 °C, 6 bar (abs)
ApprovalsIEEE 382-2006

How it compares with similar models

ParameterSAI/SARI multi-turn actuators for nuclear plants (inside containment), 10–6400 NmSAN/SARN multi-turn actuators for nuclear plants (outside containment), 10–6400 NmSA multi-turn actuators, torque 10–32000 Nm, 4–180 1/min, IP68SAR multi-turn actuators for modulating duty, torque 15–4000 Nm
Typemulti-turn actuators for nuclear power plants, inside containmentmulti-turn actuators for nuclear power plants, outside containmentmulti-turn actuatormulti-turn actuator for modulating duty
DutySAI: open-close and positioning; SARI: modulatingSAN: open-close and positioning; SARN: modulatingopen-close and positioning duty (classes A and B), S2 - 15 minmodulating duty (class C) S4 - 25 %
Torque range10 Nm to 6400 Nm10 Nm to 6400 Nm10 Nm to 32000 Nm15 Nm to 4000 Nm
Output speeds4 1/min to 180 1/min4 1/min to 180 1/min4 1/min to 180 1/min4 1/min to 90 1/min
Motors3-phase AC3-phase AC3-phase AC, 1-phase AC and DC3-phase and 1-phase AC
Ambient temperature-30 °C to +80 °C-30 °C to +80 °C-30 °C to +70 °C-30 °C to +70 °C

Request a price and lead time

SAI/SARI multi-turn actuators for nuclear plants (inside containment), 10–6400 Nm. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Where are SAI/SARI actuators used?

In nuclear power plants for valve automation, inside containment.

What LOCA/DBE resistance is given?

A short-time maximum of 220 °C at 6 bar (abs).

Which standard are the actuators qualified to?

IEEE 382-2006.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides