SAI/SARI multi-turn actuators for nuclear plants (inside containment), 10–6400 Nm
SAI/SARI are multi-turn actuators for valve automation in nuclear power plants, used inside containment. They are qualified to IEEE 382-2006 and cover torques of 10 Nm to 6400 Nm.
- Type
- multi-turn actuators for nuclear power plants, inside containment
- Duty
- SAI: open-close and positioning; SARI: modulating
- Torque range
- 10 Nm to 6400 Nm
- Output speeds
- 4 1/min to 180 1/min
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Valves in nuclear power plants are automated by the SAI/SARI type range. The actuators are used inside containment and are qualified in compliance with IEEE 382-2006. DBE resistant SAI/SARI actuators can take over safety functions under DBE conditions. SAI multi-turn actuators serve open-close duty and positioning duty, while SARI actuators are designed for modulating duty.
Torque is 10 Nm to 6400 Nm and output speed is 4 1/min to 180 1/min. The actuator senses limits and torque, runs on 3-phase AC motors and has a handwheel for manual operation. Enclosure protection is IP68 and corrosion protection is KS.
The ambient temperature range is -30 °C to +80 °C. LOCA/DBE resistance is given as a short-time maximum of 220 °C at 6 bar (abs). Options are a mechanical position indicator, a stem protection tube and wet paint.
The design is light and compact with simple installation. Electrical connection uses the plug/socket connector (terminals as an option), cable entries come in different versions and valve attachments follow DIN and ISO standards.
Technical specifications
| Type | multi-turn actuators for nuclear power plants, inside containment |
|---|---|
| Duty | SAI: open-close and positioning; SARI: modulating |
| Torque range | 10 Nm to 6400 Nm |
| Output speeds | 4 1/min to 180 1/min |
| Motors | 3-phase AC |
| Enclosure protection | IP68 |
| Corrosion protection | KS |
| Ambient temperature | -30 °C to +80 °C |
| LOCA/DBE resistance | for a short time max. 220 °C, 6 bar (abs) |
| Approvals | IEEE 382-2006 |
How it compares with similar models
| Parameter | SAI/SARI multi-turn actuators for nuclear plants (inside containment), 10–6400 Nm | SAN/SARN multi-turn actuators for nuclear plants (outside containment), 10–6400 Nm | SA multi-turn actuators, torque 10–32000 Nm, 4–180 1/min, IP68 | SAR multi-turn actuators for modulating duty, torque 15–4000 Nm |
|---|---|---|---|---|
| Type | multi-turn actuators for nuclear power plants, inside containment | multi-turn actuators for nuclear power plants, outside containment | multi-turn actuator | multi-turn actuator for modulating duty |
| Duty | SAI: open-close and positioning; SARI: modulating | SAN: open-close and positioning; SARN: modulating | open-close and positioning duty (classes A and B), S2 - 15 min | modulating duty (class C) S4 - 25 % |
| Torque range | 10 Nm to 6400 Nm | 10 Nm to 6400 Nm | 10 Nm to 32000 Nm | 15 Nm to 4000 Nm |
| Output speeds | 4 1/min to 180 1/min | 4 1/min to 180 1/min | 4 1/min to 180 1/min | 4 1/min to 90 1/min |
| Motors | 3-phase AC | 3-phase AC | 3-phase AC, 1-phase AC and DC | 3-phase and 1-phase AC |
| Ambient temperature | -30 °C to +80 °C | -30 °C to +80 °C | -30 °C to +70 °C | -30 °C to +70 °C |
Request a price and lead time
SAI/SARI multi-turn actuators for nuclear plants (inside containment), 10–6400 Nm. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Where are SAI/SARI actuators used?
In nuclear power plants for valve automation, inside containment.
What LOCA/DBE resistance is given?
A short-time maximum of 220 °C at 6 bar (abs).
Which standard are the actuators qualified to?
IEEE 382-2006.