SAREx explosion-proof multi-turn actuators for modulating duty, 15–4000 Nm
SAREx is an explosion-proof multi-turn actuator for modulating duty. Torque is 15 Nm to 4000 Nm, modulating torque 15 Nm to 1600 Nm and output speed 4 1/min to 90 1/min.
- Type
- explosion-proof multi-turn actuator for modulating duty
- Duty
- modulating duty (class C)
- Torque range
- 15 Nm to 4000 Nm
- Modulating torque range
- 15 Nm to 1600 Nm
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Plants with potentially explosive atmospheres call for explosion-proof devices such as the SAREx, a multi-turn actuator for modulating duty. These devices are designed so that they do not act as an ignition source: they generate neither ignition sparks nor hot surface temperatures. Certification is performed in close collaboration with national and international certification bodies.
Torque is 15 Nm to 4000 Nm, modulating torque is 15 Nm to 1600 Nm and output speed is 4 1/min to 90 1/min, with a maximum of 1200 c/h. The actuator senses limits and torque, runs on 3-phase AC, 1-phase AC and DC motors, and has a handwheel for manual operation. Enclosure protection is IP68, corrosion protection is KS and the ambient temperature range is -30 °C to +70 °C.
ATEX markings are II 2G Ex db eb IIC (IIB) T4 (T3) Gb, II 2G Ex db IIC (IIB) T4 (T3) Gb and II 2D Ex tb IIIC T130°C (T190°C) Db. IECEx markings are Ex db eb IIC (IIB) T4 (T3) Gb, Ex db IIC (IIB) T4 (T3) Gb and Ex tb IIIC T130°C (T190°C) Db. FM markings are CLASS I DIV 1 GROUPS (B), C, D T4 (T3C); CLASS II DIV 1 GROUPS E, F, G T4 (T3C); CLASS III DIV 1 T4 (T3).
Options include intermediate position switches, switches in tandem version, a position transmitter, a magnetic limit and torque transmitter and a mechanical position indicator. Functional safety reaches up to SIL 2 in selected configurations and up to SIL 3 with ACExC 01.2 SIL actuator controls. Electrical connection uses the manufacturer's plug/socket connector, with a plug-in terminal connection as an option.
Technical specifications
| Type | explosion-proof multi-turn actuator for modulating duty |
|---|---|
| Duty | modulating duty (class C) |
| Torque range | 15 Nm to 4000 Nm |
| Modulating torque range | 15 Nm to 1600 Nm |
| Output speeds | 4 1/min to 90 1/min |
| Number of starts (max.) | 1200 c/h |
| Enclosure protection | IP68 |
| Corrosion protection | KS |
| Ambient temperature | -30 °C to +70 °C |
| ATEX explosion protection | II 2G Ex db eb IIC (IIB) T4 (T3) Gb; II 2G Ex db IIC (IIB) T4 (T3) Gb; II 2D Ex tb IIIC T130°C (T190°C) Db |
| FM explosion protection | CLASS I DIV 1 GROUPS (B), C, D T4 (T3C); CLASS II DIV 1 GROUPS E, F, G T4 (T3C); CLASS III DIV 1 T4 (T3) |
| IECEx explosion protection | Ex db eb IIC (IIB) T4 (T3) Gb; Ex db IIC (IIB) T4 (T3) Gb; Ex tb IIIC T130°C (T190°C) Db |
How it compares with similar models
| Parameter | SAREx explosion-proof multi-turn actuators for modulating duty, 15–4000 Nm | SAR multi-turn actuators for modulating duty, torque 15–4000 Nm | SAR-UW underwater multi-turn actuator for modulating duty, 15–4000 Nm | SAEx explosion-proof multi-turn actuators, torque 10–16000 Nm |
|---|---|---|---|---|
| Type | explosion-proof multi-turn actuator for modulating duty | multi-turn actuator for modulating duty | multi-turn actuator for underwater use | explosion-proof multi-turn actuator |
| Duty | modulating duty (class C) | modulating duty (class C) S4 - 25 % | modulating | — |
| Torque range | 15 Nm to 4000 Nm | 15 Nm to 4000 Nm | 15 Nm to 4000 Nm | 10 Nm to 16000 Nm |
| Output speeds | 4 1/min to 90 1/min | 4 1/min to 90 1/min | 4 1/min to 90 1/min | 4 1/min to 180 1/min |
| Enclosure protection | IP68 | IP68 | for continuous underwater use, 15 m | IP68 |
| Corrosion protection | KS | KS | Im1, Im2, Im3 | KS |
Request a price and lead time
SAREx explosion-proof multi-turn actuators for modulating duty, 15–4000 Nm. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which explosion-protection approvals are listed for the SAREx?
ATEX, FM and IECEx; for example II 2G Ex db eb IIC (IIB) T4 (T3) Gb for ATEX.
What is the modulating torque range?
15 Nm to 1600 Nm, within an actuator torque range of 15 Nm to 4000 Nm.
What functional safety is available?
Up to SIL 2 in selected configurations and up to SIL 3 with ACExC 01.2 SIL actuator controls.
Similar equipment from other manufacturers