SAREx explosion-proof multi-turn actuators for modulating duty, 15–4000 Nm

SAREx is an explosion-proof multi-turn actuator for modulating duty. Torque is 15 Nm to 4000 Nm, modulating torque 15 Nm to 1600 Nm and output speed 4 1/min to 90 1/min.

Type
explosion-proof multi-turn actuator for modulating duty
Duty
modulating duty (class C)
Torque range
15 Nm to 4000 Nm
Modulating torque range
15 Nm to 1600 Nm

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Plants with potentially explosive atmospheres call for explosion-proof devices such as the SAREx, a multi-turn actuator for modulating duty. These devices are designed so that they do not act as an ignition source: they generate neither ignition sparks nor hot surface temperatures. Certification is performed in close collaboration with national and international certification bodies.

Torque is 15 Nm to 4000 Nm, modulating torque is 15 Nm to 1600 Nm and output speed is 4 1/min to 90 1/min, with a maximum of 1200 c/h. The actuator senses limits and torque, runs on 3-phase AC, 1-phase AC and DC motors, and has a handwheel for manual operation. Enclosure protection is IP68, corrosion protection is KS and the ambient temperature range is -30 °C to +70 °C.

ATEX markings are II 2G Ex db eb IIC (IIB) T4 (T3) Gb, II 2G Ex db IIC (IIB) T4 (T3) Gb and II 2D Ex tb IIIC T130°C (T190°C) Db. IECEx markings are Ex db eb IIC (IIB) T4 (T3) Gb, Ex db IIC (IIB) T4 (T3) Gb and Ex tb IIIC T130°C (T190°C) Db. FM markings are CLASS I DIV 1 GROUPS (B), C, D T4 (T3C); CLASS II DIV 1 GROUPS E, F, G T4 (T3C); CLASS III DIV 1 T4 (T3).

Options include intermediate position switches, switches in tandem version, a position transmitter, a magnetic limit and torque transmitter and a mechanical position indicator. Functional safety reaches up to SIL 2 in selected configurations and up to SIL 3 with ACExC 01.2 SIL actuator controls. Electrical connection uses the manufacturer's plug/socket connector, with a plug-in terminal connection as an option.

Technical specifications

Typeexplosion-proof multi-turn actuator for modulating duty
Dutymodulating duty (class C)
Torque range15 Nm to 4000 Nm
Modulating torque range15 Nm to 1600 Nm
Output speeds4 1/min to 90 1/min
Number of starts (max.)1200 c/h
Enclosure protectionIP68
Corrosion protectionKS
Ambient temperature-30 °C to +70 °C
ATEX explosion protectionII 2G Ex db eb IIC (IIB) T4 (T3) Gb; II 2G Ex db IIC (IIB) T4 (T3) Gb; II 2D Ex tb IIIC T130°C (T190°C) Db
FM explosion protectionCLASS I DIV 1 GROUPS (B), C, D T4 (T3C); CLASS II DIV 1 GROUPS E, F, G T4 (T3C); CLASS III DIV 1 T4 (T3)
IECEx explosion protectionEx db eb IIC (IIB) T4 (T3) Gb; Ex db IIC (IIB) T4 (T3) Gb; Ex tb IIIC T130°C (T190°C) Db

How it compares with similar models

ParameterSAREx explosion-proof multi-turn actuators for modulating duty, 15–4000 NmSAR multi-turn actuators for modulating duty, torque 15–4000 NmSAR-UW underwater multi-turn actuator for modulating duty, 15–4000 NmSAEx explosion-proof multi-turn actuators, torque 10–16000 Nm
Typeexplosion-proof multi-turn actuator for modulating dutymulti-turn actuator for modulating dutymulti-turn actuator for underwater useexplosion-proof multi-turn actuator
Dutymodulating duty (class C)modulating duty (class C) S4 - 25 %modulating—
Torque range15 Nm to 4000 Nm15 Nm to 4000 Nm15 Nm to 4000 Nm10 Nm to 16000 Nm
Output speeds4 1/min to 90 1/min4 1/min to 90 1/min4 1/min to 90 1/min4 1/min to 180 1/min
Enclosure protectionIP68IP68for continuous underwater use, 15 mIP68
Corrosion protectionKSKSIm1, Im2, Im3KS

Request a price and lead time

SAREx explosion-proof multi-turn actuators for modulating duty, 15–4000 Nm. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which explosion-protection approvals are listed for the SAREx?

ATEX, FM and IECEx; for example II 2G Ex db eb IIC (IIB) T4 (T3) Gb for ATEX.

What is the modulating torque range?

15 Nm to 1600 Nm, within an actuator torque range of 15 Nm to 4000 Nm.

What functional safety is available?

Up to SIL 2 in selected configurations and up to SIL 3 with ACExC 01.2 SIL actuator controls.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides