Rectiverter Power Core 6–18 kVA — combined AC and DC power systems
Rectiverter Power Core combines AC and DC power supply in one unit: it simultaneously provides backup of a 230 or 115 V AC load, supplies a DC load (48, 110 or 220 V) and charges the battery.
- AC power
- up to 6 kVA (1ph) / 18 kVA (3ph)
- DC power
- up to 16.8–24 kW; 4.8 kW (110 V DC)
- Maximum DC current
- 50–300 A
- Input configuration
- 230 V AC 1-phase / 230/400 V AC 3-phase
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Rectiverter Power Core combines AC and DC power supply in one unit: it simultaneously provides backup of a 230 or 115 V AC load, supplies a DC load (48, 110 or 220 V) and charges the battery. The combined output power for AC and DC is limited to 8 kW in single-phase versions; the AC limit is set up to 6 kVA, and the DC limit is up to 16–24 kW depending on the configuration. Three-phase versions (18 kVA) are suitable for distributing the load between phases.
Main features: a single unit instead of separate rectifier and inverter; adjustable AC and DC voltage limits for the load; single-phase or three-phase TN mains input; DC output 48, 110 or 220 V; modular design based on Flatpack2 HE rectifiers; up to 18 fuses / load breakers.
Versions in the series: 6 kVA 1ph (including MB version), 6 kVA AC + 16.8–24 kW DC, 18 kVA 3ph; DC 48, 110 or 220 V.
Technical data (depends on version): AC power — up to 6 kVA (1ph) / 18 kVA (3ph); DC power — up to 16.8–24 kW; 4.8 kW (110 V DC); Maximum DC current — 50–300 A; Input configuration — 230 V AC 1-phase / 230/400 V AC 3-phase; Number of fuses — up to 18, current up to 10 A; Operating temperature — −40…+75 °C.
Applications: power engineering: substations, switchgear, protective relay systems; railways, metro and industry; oil and gas and marine sectors.
The product listing provides a technical description in Ukrainian and a specification table. The specific version, power, voltage and configuration are selected to suit the project; please clarify the parameters with a USK ENERGY manager. Supplied to order, with documents for customs clearance.
Technical specifications
| AC power | up to 6 kVA (1ph) / 18 kVA (3ph) |
|---|---|
| DC power | up to 16.8–24 kW; 4.8 kW (110 V DC) |
| Maximum DC current | 50–300 A |
| Input configuration | 230 V AC 1-phase / 230/400 V AC 3-phase |
| Number of fuses | up to 18, current up to 10 A |
| Operating temperature | −40…+75 °C |