Rectiverter Indoor / Outdoor 6 kVA AC + 12.8–24 kW DC — combined power systems for indoor and outdoor use

Rectiverter Indoor and Outdoor systems combine AC and DC power supply in one unit: they back up a 230 V AC load and supply a 48 V DC load while charging batteries. The total DC output is configurable for loads up to 24 kW, with AC limited to 6 kVA.

AC power
up to 6 kVA
DC power
21 kW (Outdoor) / 24 kW (Indoor)
Maximum DC current
437 A / 500 A
Input configuration
230/400 V AC 3-phase (Y)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Rectiverter Indoor and Outdoor systems combine AC and DC power supply in one unit: they back up a 230 V AC load and supply a 48 V DC load while charging batteries. The total DC output is configurable for loads up to 24 kW, with AC limited to 6 kVA. The indoor version is installed in IFC and FPC platform cabinets; the outdoor version is built into a Type 3 cabinet with an IP55 degree of protection.

Main features: single AC + DC unit; DC output 12.8–21 kW (Outdoor) and 12.8–24 kW (Indoor); Outdoor version — Type 3 cabinet, IP55; installation into IFC and FPC platform cabinets (Indoor).

Versions in the series: Outdoor 6 kVA AC + 12.8–21 kW DC; Indoor 6 kVA AC + 12.8–24 kW DC.

Technical data (depends on version): AC power — up to 6 kVA; DC power — 21 kW (Outdoor) / 24 kW (Indoor); Maximum DC current — 437 A / 500 A; Input configuration — 230/400 V AC 3-phase (Y); Number of fuses — 4 / 10.

Applications: telecommunications and network nodes; power engineering and industry; outdoor sites without a building (Outdoor).

The product listing provides a technical description in Ukrainian and a specification table. The specific version, power, voltage and configuration are selected to suit the project; please clarify the parameters with a USK ENERGY manager. Supplied to order, with documents for customs clearance.

Technical specifications

AC powerup to 6 kVA
DC power21 kW (Outdoor) / 24 kW (Indoor)
Maximum DC current437 A / 500 A
Input configuration230/400 V AC 3-phase (Y)
Number of fuses4 / 10

Request a price and lead time

Rectiverter Indoor / Outdoor 6 kVA AC + 12.8–24 kW DC — combined power systems for indoor and outdoor use. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides