International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Flatpack2 Integrated (19″, 2U, 4U, 24 kW) — integrated DC power systems

Flatpack2 Integrated are ready-made DC power units based on Flatpack2 rectifiers: rectifiers, controller and distribution are combined in one housing. The systems are intended for switchgear, telecommunication equipment, emergency lighting and alarm systems.

DC power
up to 12 kW (19″ 2U); up to 24 kW
Maximum DC current
300 A
Input voltage
230 V AC 1-phase, up to 305 V AC / 300 V DC
Operating temperature
−40…+55 °C

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Flatpack2 Integrated are ready-made DC power units based on Flatpack2 rectifiers: rectifiers, controller and distribution are combined in one housing. The systems are intended for switchgear, telecommunication equipment, emergency lighting and alarm systems. The wide output voltage range allows parallel operation with all types of stationary batteries, including lead-acid and nickel-cadmium. Measurement and alarm functions can be extended with Flexi-Monitor modules and a relay board.

Main features: 19-inch housing 2U or 4U with Smartpack2 / Smartpack S controller; rectifiers, controller and distribution in one unit; power up to 12–24 kW, current up to 300 A; deep battery discharge protection (LVBD) and load disconnection (LVLD); 48 V Hybrid version.

Versions in the series: Integrated 19″, 2U Integrated, 4U Dist, 48 V / 24 kW, Integrated system, 48 V Hybrid.

Technical data (depends on version): DC power — up to 12 kW (19″ 2U); up to 24 kW; Maximum DC current — 300 A; Input voltage — 230 V AC 1-phase, up to 305 V AC / 300 V DC; Operating temperature — −40…+55 °C; Storage temperature — −40…+85 °C.

Applications: switchgear and substations; telecommunications; emergency lighting and alarm systems.

The product listing provides a technical description in Ukrainian and a specification table. The specific version, power, voltage and configuration are selected to suit the project; please clarify the parameters with a USK ENERGY manager. Supplied to order, with documents for customs clearance.

Technical specifications

DC powerup to 12 kW (19″ 2U); up to 24 kW
Maximum DC current300 A
Input voltage230 V AC 1-phase, up to 305 V AC / 300 V DC
Operating temperature−40…+55 °C
Storage temperature−40…+85 °C

Request a price and lead time

Flatpack2 Integrated (19″, 2U, 4U, 24 kW) — integrated DC power systems. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Similar equipment from other manufacturers