LRGBJ Current Transformers for Shunt Capacitor Bank Protection, 35 to 500 kV

Very low ratio current transformers protect shunt capacitor banks rated from 35 to 500 kV. Dry HV DryShield® insulation and metering accuracy classes give sensitive detection of small currents at high voltage.

Rated voltage
35, 66, 110, 220, 330, 500 kV
Highest equipment voltage Um
40.5; 72.5; 145; 252; 363; 550 kV
One-minute power frequency withstand, dry
100; 155; 275; 460; 510; 680 kV
One-minute power frequency withstand, wet
80; 140; 230; 395; 510; 680 kV

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

These current transformers are intended for protecting shunt capacitor banks, where very small currents must be detected on the high voltage side. They carry all the features of the base LRGBJ series, together with additional characteristics for this particular application. According to the manufacturer, this approach brings a noticeable saving in capacitor bank design and a high level of protection.

The insulation uses dry HV DryShield® technology with no oil. Rated primary current covers 0.5, 1, 2, 2.5, 3, 4, 5 and 10 A, and the secondary current is either 1 A or 5 A. For maximum detection sensitivity, metering accuracy classes 0.2S, 0.2, 0.5S and 0.5 are used. The rated short-time thermal current Ith is 1.8 kA for most steps, and 2.5 and 4.5 kA for the higher steps.

The rated voltage series covers 35, 66, 110, 220, 330 and 500 kV, with equipment highest voltages Um of 40.5, 72.5, 145, 252, 363 and 550 kV. The one-minute power frequency withstand voltage lies between 100 and 680 kV dry and between 80 and 680 kV wet. The rated lightning impulse withstand voltage ranges from 185 kV for the 35 kV class to 1550 kV for the 500 kV class. For the 330 and 500 kV classes, a switching impulse of 950 and 1175 kV is also specified.

The products conform to IEC 61869-2, IEEE C57.13 and CAN/CSA C61869-2. All other characteristics not listed in the table match the base LRGBJ series and are defined by its specification. These transformers are used in power systems where shunt capacitor banks connected to the high voltage network provide reactive power compensation.

Technical specifications

Rated voltage35, 66, 110, 220, 330, 500 kV
Highest equipment voltage Um40.5; 72.5; 145; 252; 363; 550 kV
One-minute power frequency withstand, dry100; 155; 275; 460; 510; 680 kV
One-minute power frequency withstand, wet80; 140; 230; 395; 510; 680 kV
Switching impulse (Um 363 / 550 kV)950 / 1175 kV
Lightning impulse185; 350; 650; 1050; 1175; 1550 kV
Rated primary current0.5; 1; 2; 2.5; 3; 4; 5; 10 A
Short-time thermal current Ithup to 4.5 kA
Rated secondary current1 A, 5 A
Accuracy classes0.2S, 0.2, 0.5S, 0.5
Insulationdry, HV DryShield®
StandardsIEC 61869-2, IEEE C57.13, CAN/CSA C61869-2

Request a price and lead time

LRGBJ Current Transformers for Shunt Capacitor Bank Protection, 35 to 500 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which voltages are these current transformers made for?

Rated voltages of 35, 66, 110, 220, 330 and 500 kV, with equipment highest voltages from 40.5 to 550 kV.

What is the lowest primary current available?

The rated primary current starts at 0.5 A and the top of the range is 10 A; the secondary current is 1 A or 5 A.

Which accuracy classes are offered?

Metering classes 0.2S, 0.2, 0.5S and 0.5, which give the most sensitive detection of small currents.