JGF — SF6 outdoor current transformer, 245–550 kV

JGF SF6 current transformer for 245–550 kV substations with a primary current of up to 5000 A. The cores are housed in a cast aluminium head, and the gas density is monitored. For temperatures down to −60 °C the unit is filled with a gas mixture.

Rated voltage
245–550 kV
Primary current
up to 5000 A
Secondary current
1 / 5 A
Short-time thermal current
up to 80 kA / 3 s

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

SF6 insulation, polymer external insulator. With pure SF6 the transformer operates down to −40 °C; for colder climates a gas mixture is used. Secondary current 1 or 5 A, up to 8 secondary windings. Accuracy classes 0.1–3, P, PR, PX, TPS, TPX, TPY and TPZ, from revenue metering to relay protection. Short-time thermal current up to 80 kA for 3 s, dynamic current up to 200 kA.

Technical specifications

Rated voltage245–550 kV
Primary currentup to 5000 A
Secondary current1 / 5 A
Short-time thermal currentup to 80 kA / 3 s
Dynamic withstand currentup to 200 kA
Accuracy classes0.1–3; P; PR; PX; TPS; TPX; TPY; TPZ
Number of secondary windingsup to 8
InsulationSF6, polymer insulator
Temperaturedown to −40 °C (SF6), down to −60 °C (gas mixture)

Replacement for

ТОГФ-220, ТРГ-220, ТРГ-500 (SF6-insulated)

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

JGF — SF6 outdoor current transformer, 245–550 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 31 29 00
HS, 6 digits8504 31
CN (EU)8504 31 29
HTSUS (USA)8504 31 20 00
China customs tariff8504 31 10 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What voltage and current is the JGF rated for?

Rated voltage 245–550 kV, primary current up to 5000 A, secondary current 1 or 5 A.

Down to what temperature does the transformer operate?

Down to −40 °C with SF6 filling. For temperatures down to −60 °C it is filled with a gas mixture.

What are the accuracy classes and short-circuit withstand?

Classes 0.1–3, P, PR, PX, TPS, TPX, TPY, TPZ. Thermal withstand up to 80 kA / 3 s, dynamic up to 200 kA.