EJOF — oil-paper combined current and voltage transformer, 24–170 kV

EJOF combined instrument transformer with oil-paper insulation for outdoor substations of 24–170 kV, primary current up to 5000 A. The CT is located in the head and the VT in the lower tank.

Rated voltage
24–170 kV
Primary current
up to 5000 A
Short-time thermal current
up to 63 kA / 1 s
CT accuracy classes
0.1–3; 0.2S; 0.5S; P; PR; PX; TPX; TPY; TPZ

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The unit replaces separate CTs and VTs and saves space in the outdoor switchyard. Short-time thermal current up to 63 kA for 1 s. Up to 7 CT windings and up to 5 VT windings. CT accuracy classes 0.1–3, 0.2S, 0.5S, P, PR, PX, TPX, TPY and TPZ; VT classes 0.1–3, 3P and 6P. So the unit supplies signals for metering and for protection.

Technical specifications

Rated voltage24–170 kV
Primary currentup to 5000 A
Short-time thermal currentup to 63 kA / 1 s
CT accuracy classes0.1–3; 0.2S; 0.5S; P; PR; PX; TPX; TPY; TPZ
VT accuracy classes0.1–3; 3P; 6P
Windingsup to 7 CT windings, up to 5 VT windings
Insulationoil-paper

Replacement for

no direct analog (combined CT + VT units were not produced in series); pairs ТФЗМ-110Б + НАМИ-110, ТОЛ-35 + ЗНОМ-35

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

EJOF — oil-paper combined current and voltage transformer, 24–170 kV. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 31 21 00
8504 31 29 00
HS, 6 digits8504 31
CN (EU)8504 31 21
8504 31 29
HTSUS (USA)8504 31 20 00
China customs tariff8504 31 10 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What does the combined EJOF offer compared with separate CTs and VTs?

It replaces separate CTs and VTs and saves space in the outdoor switchyard. The CT is located in the head and the VT in the lower tank.

What voltage and current is the EJOF rated for?

Rated voltage 24–170 kV, primary current up to 5000 A, thermal withstand up to 63 kA / 1 s.

Are there classes for revenue metering?

Yes, the CT is available in classes 0.2S and 0.5S, as well as 0.1–3 and the protection classes P, PR, PX, TPX, TPY, TPZ.