International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

Eco Fluid CT / Combined: ester-insulated current transformers up to 550 kV and combined units

Eco Fluid is available as current transformers up to 550 kV and combined CT/VT units up to 145 kV with paper-ester insulation. They directly replace oil-filled units of the same dimensions in water protection zones and underground substations.

Voltage class
CT up to 550 kV; combined up to 145 kV
Primary current
up to 5000 A
Insulation
paper impregnated with biodegradable ester (OECD 301)
External insulation
porcelain or composite

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Primary current up to 5000 A. The paper insulation is impregnated with a biodegradable ester per OECD 301, which makes the unit suitable for water protection zones. External insulation is porcelain or composite. The dimensions match the oil-filled equivalents, so the unit is installed in place of an oil-filled one without changing the layout.

Technical specifications

Voltage classCT up to 550 kV; combined up to 145 kV
Primary currentup to 5000 A
Insulationpaper impregnated with biodegradable ester (OECD 301)
External insulationporcelain or composite
Dimensionsmatch oil-filled equivalents

Replacement for

ТФЗМ-110Б, ТФЗМ-220Б, ТФУМ-330, ТФРМ-500, ТФРМ-750 (oil-filled); there is no direct equivalent with ester fluid

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

Eco Fluid CT / Combined: ester-insulated current transformers up to 550 kV and combined units. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 31 21 00
8504 31 29 00
HS, 6 digits8504 31
CN (EU)8504 31 21
8504 31 29
HTSUS (USA)8504 31 20 00
China customs tariff8504 31 10 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What voltage are Eco Fluid CT and combined units made for?

Current transformers up to 550 kV, combined CT/VT units up to 145 kV. Primary current up to 5000 A.

Can they replace oil-filled current transformers?

Yes, the dimensions match oil-filled equivalents of the same size. The replacement is direct.

Where is ester insulation especially appropriate?

In water protection zones and at underground substations. The ester is biodegradable per OECD 301.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides