OBCT, EGCT, BGCT, DBCT, SBCT, RELV and CRT current transformers for metering and protection
This family of current transformers for protection and commercial metering includes built-in bushing, generator, surface-mounted, zero-sequence and CRT metering types. Accuracy classes start at 0.15S, with burdens of B0.1 to B1.8 or 2.5 to 45 VA.
- Purpose
- protection and metering, metering
- Types
- built-in bushing (oil-filled, dry), generator, surface-mounted, zero-sequence, metering
- Primary current OBCT, DBCT
- above 8000 A
- Metering class OBCT
- 0.15S…2.4 / 0.2S…5.0
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
These current transformers are used in power generation, distribution networks and industrial processes to measure current, meter electricity, provide protection, detect faults and support operational control. Most types are built for a specific application, and their characteristics can be matched to a transformer already installed on site.
The OBCT is fitted inside oil-filled equipment over the bushing neck. It works with primary currents above 8000 A, has cores with an air gap for controlling residual magnetism and transient response, and is made with one, two or several ratios (SR, DR, MR). The dry-type DBCT is also mounted inside equipment, under an outer cover or in a sealed cabinet, with primary currents above 8000 A and secondary leads terminated with terminals or flexible wires.
The EGCT and BGCT are intended for generator bushings. The EGCT is compound-filled for heavy operating conditions and has a Sky Grey (ANSI 70) housing. The BGCT is board-mounted and can be supplied as ready-made multi-core assemblies, which shortens downtime during emergency repairs. Both types are made with a single ratio (SR) only. Windings can have extra test taps, and conduit openings are threaded up to 1.5 inch NPT or unthreaded up to 52 mm. The rated current factor is up to 1.0 at 55°C.
The SBCT is installed externally by slipping it over the bushing. It is supplied with earthing shields and site mounting kits, and a two-core design is possible with 3 kV insulation between the cores. The RELV is a rectangular, cast, surface-mounted zero-sequence transformer for low-voltage networks that detects current imbalance. The CRT metering transformers have a 5.5 inch (140 mm) window and dimensions of 8.25 x 9.84 x 2.88 inch (210 x 250 x 73 mm). The CRT-15E holds an error of +/- 0.15% from 1% of rated current up to the rated current factor, the CRT-15S meets class 0.15S from 5% of rated current, the CRT-15 meets class 0.15 and the CRT-3 meets class 0.3.
Technical specifications
| Purpose | protection and metering, metering |
|---|---|
| Types | built-in bushing (oil-filled, dry), generator, surface-mounted, zero-sequence, metering |
| Primary current OBCT, DBCT | above 8000 A |
| Metering class OBCT | 0.15S…2.4 / 0.2S…5.0 |
| Metering class EGCT, BGCT | 0.15S…0.6 (IEEE) / 0.2S…0.5 (IEC) |
| Burden | B0.1…B1.8 / 2.5…45 VA |
| Ratios | SR, DR, MR (OBCT); SR (EGCT, BGCT) |
| Rated current factor EGCT, BGCT | up to 1.0 at 55°C |
| Conduit openings | threaded up to 1.5 inch NPT or unthreaded up to 52 mm |
| Insulation between cores SBCT | 3 kV |
| CRT window | 5.5 inch (140 mm) |
| CRT dimensions | 8.25 x 9.84 x 2.88 inch (210 x 250 x 73 mm) |
| Accuracy CRT-15E / CRT-15S | +/- 0.15% from 1% / from 5% of rated |
| Housing colour | Sky Grey (ANSI 70), black |
Part numbers
Show all part numbers (10)
OBCT, EGCT, BGCT, DBCT, SBCT, RELV, CRT-15E, CRT-15S, CRT-15, CRT-3
Request a price and lead time
OBCT, EGCT, BGCT, DBCT, SBCT, RELV and CRT current transformers for metering and protection. We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Questions and answers
Which type suits currents above 8000 A?
The built-in bushing OBCT for oil-filled equipment and the dry-type DBCT are both rated for primary currents above 8000 A.
Can a transformer already installed on a generator be replaced?
Yes. EGCT and BGCT are made to suit the characteristics of an existing transformer, and BGCT can be supplied as ready-made multi-core assemblies.
What accuracy do the CRT metering transformers have?
The CRT-15E and CRT-15S hold +/- 0.15% from 1% or 5% of rated current respectively, the CRT-15 meets class 0.15 and the CRT-3 meets class 0.3.