AKA / JK-GCT / JKQ / AKQ current transformers for generator busducts up to 50 kA

Heavy-current transformers for power plants, with primary current up to 50000 A. They are installed in phase-segregated busducts, on generator terminals and in generator circuit breakers.

Primary current
up to 50000 A
AKA
for phase-segregated busduct
JK-GCT / JKQ
for generator terminals
AKQ
for 12–36 kV generator circuit breakers, up to 3 cores

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

AKA is built into a phase-segregated busduct, while JK-GCT and JKQ are mounted on the generator terminals. AKQ is intended for 12–36 kV generator circuit breakers and has up to 3 cores. The cast multi-core JKO is rated up to 15000 A. Ring-type current transformers with a window of up to 1200 mm are also made to order. A version for hazardous area zone 2 is available as an option.

Technical specifications

Primary currentup to 50000 A
AKAfor phase-segregated busduct
JK-GCT / JKQfor generator terminals
AKQfor 12–36 kV generator circuit breakers, up to 3 cores
JKOcast multi-core, up to 15000 A
Optionsversion for hazardous area zone 2

Replacement for

ТШЛ-20, ТШВ-15, ТШВ-24 (generator bus-type up to 24 kA); above 24 kA there is no direct analogue

selected by purpose and main parameters, please confirm with our manager

Request a price and lead time

AKA / JK-GCT / JKQ / AKQ current transformers for generator busducts up to 50 kA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8504 31 29 00
HS, 6 digits8504 31
CN (EU)8504 31 29
HTSUS (USA)8504 31 20 00
China customs tariff8504 31 10 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Which current transformer is needed for a generator circuit breaker?

AKQ for 12–36 kV generator circuit breakers, with up to 3 cores.

What is the maximum current the current transformers are made for?

Primary current up to 50000 A. Ring-type current transformers made to order have a window of up to 1200 mm.

Is a version for hazardous areas available?

Yes, as an option for hazardous area zone 2.