International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

UK — compact concrete substation (unattended)

UK is a compact unattended substation made of seamless monolithic reinforced concrete, 1.47–1.82 m high above ground. It has a built-in raised-floor foundation and a removable roof. Transfer station (ÜST) versions without a transformer and LV panel are available.

Height above ground
1.47–1.82 m
Versions
3-chamber (UK 1700-28 … UK 2600-35), 1-chamber distribution (UK 1700-15 … UK 2600-17), with access from three sides (UKL)
Dimensions
from 1.58 × 1.90 × 2.38 m to 3.60 × 2.40 × 2.65 m
Concrete
monolithic reinforced concrete C35/45, DIN EN 206-1/DIN 1045-2

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Versions: 3-chamber (UK 1700-28 … UK 2600-35), 1-chamber distribution (UK 1700-15 … UK 2600-17) and UKL with access from three sides. Dimensions from 1.58 × 1.90 × 2.38 m to 3.60 × 2.40 × 2.65 m. Concrete C35/45 to DIN EN 206-1/DIN 1045-2. The transformer chamber is built as an oil-collecting tray of FD-grade concrete. A removable roof slab opens the chamber for transformer replacement.

Technical specifications

Height above ground1.47–1.82 m
Versions3-chamber (UK 1700-28 … UK 2600-35), 1-chamber distribution (UK 1700-15 … UK 2600-17), with access from three sides (UKL)
Dimensionsfrom 1.58 × 1.90 × 2.38 m to 3.60 × 2.40 × 2.65 m
Concretemonolithic reinforced concrete C35/45, DIN EN 206-1/DIN 1045-2
Oil containmenttransformer chamber built as an oil-collecting tray of FD-grade concrete
Roofremovable slab for transformer replacement

Request a price and lead time

UK — compact concrete substation (unattended). We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8537 20 91 00
8537 20 99 00
HS, 6 digits8537 20
CN (EU)8537 20 91
8537 20 99
HTSUS (USA)8537 20 00 20
China customs tariff8537 20 90 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What is the height of the station above ground?

1.47–1.82 m depending on the version.

How is oil collected if the transformer leaks?

The transformer chamber is built as an oil-collecting tray of FD-grade concrete.

How is the transformer in the station replaced?

The roof slab is removed and the transformer is lifted out through the top.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides