UK — compact concrete substation (unattended)
UK is a compact unattended substation made of seamless monolithic reinforced concrete, 1.47–1.82 m high above ground. It has a built-in raised-floor foundation and a removable roof. Transfer station (ÜST) versions without a transformer and LV panel are available.
- Height above ground
- 1.47–1.82 m
- Versions
- 3-chamber (UK 1700-28 … UK 2600-35), 1-chamber distribution (UK 1700-15 … UK 2600-17), with access from three sides (UKL)
- Dimensions
- from 1.58 × 1.90 × 2.38 m to 3.60 × 2.40 × 2.65 m
- Concrete
- monolithic reinforced concrete C35/45, DIN EN 206-1/DIN 1045-2
Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.
Description
Versions: 3-chamber (UK 1700-28 … UK 2600-35), 1-chamber distribution (UK 1700-15 … UK 2600-17) and UKL with access from three sides. Dimensions from 1.58 × 1.90 × 2.38 m to 3.60 × 2.40 × 2.65 m. Concrete C35/45 to DIN EN 206-1/DIN 1045-2. The transformer chamber is built as an oil-collecting tray of FD-grade concrete. A removable roof slab opens the chamber for transformer replacement.
Technical specifications
| Height above ground | 1.47–1.82 m |
|---|---|
| Versions | 3-chamber (UK 1700-28 … UK 2600-35), 1-chamber distribution (UK 1700-15 … UK 2600-17), with access from three sides (UKL) |
| Dimensions | from 1.58 × 1.90 × 2.38 m to 3.60 × 2.40 × 2.65 m |
| Concrete | monolithic reinforced concrete C35/45, DIN EN 206-1/DIN 1045-2 |
| Oil containment | transformer chamber built as an oil-collecting tray of FD-grade concrete |
| Roof | removable slab for transformer replacement |
Request a price and lead time
UK — compact concrete substation (unattended). We reply within one business day.
Or email sales@usk.ua or call 044 339-50-20.
Customs codes
| UKTZED (Ukraine) | 8537 20 91 00 8537 20 99 00 |
|---|---|
| HS, 6 digits | 8537 20 |
| CN (EU) | 8537 20 91 8537 20 99 |
| HTSUS (USA) | 8537 20 00 20 |
| China customs tariff | 8537 20 90 00 |
Codes are for reference: the final code is determined at declaration for the specific model.
Questions and answers
What is the height of the station above ground?
1.47–1.82 m depending on the version.
How is oil collected if the transformer leaks?
The transformer chamber is built as an oil-collecting tray of FD-grade concrete.
How is the transformer in the station replaced?
The roof slab is removed and the transformer is lifted out through the top.