International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

UF serviceable concrete transformer station / technical building

UF are serviceable concrete stations of monolithic volumetric blocks for transformer substations, distribution and switching points. They are supplied with complete factory-ready electrical equipment. Internal length is 2.18–10.58 m, arc resistance IAC-AB 20 kA 1 s.

Series
UF 18, 25, 27, 30, 33, 36, 39, 42 (module width)
Internal dimensions
length 2.18–10.58 m, width 1.58–3.98 m
Module weight
≈11–65 t
Layouts
more than 150 standard

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The series UF 18, 25, 27, 30, 33, 36, 39 and 42 are named by module width, internal width 1.58–3.98 m. Module weight is about 11–65 t. More than 150 standard layouts exist. The station can stand on the ground, on a slope, or partly or fully in the ground. The enclosure is monolithic reinforced concrete C35/45, internal arc resistance verified to IEC 62271-202. Degree of protection IP23D, optionally IP34D or IP44D.

Technical specifications

SeriesUF 18, 25, 27, 30, 33, 36, 39, 42 (module width)
Internal dimensionslength 2.18–10.58 m, width 1.58–3.98 m
Module weight≈11–65 t
Layoutsmore than 150 standard
Installationabove ground, on a slope, partly or fully in the ground
Concretemonolithic reinforced concrete C35/45
Arc resistanceIAC-AB 20 kA 1 s (IEC 62271-202)
Degree of protectionIP23D, option IP34D / IP44D

Request a price and lead time

UF serviceable concrete transformer station / technical building. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8537 20 91 00
8537 20 99 00
HS, 6 digits8537 20
CN (EU)8537 20 91
8537 20 99
HTSUS (USA)8537 20 00 40
China customs tariff8537 20 90 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What are the internal dimensions of UF stations?

Length 2.18–10.58 m, width 1.58–3.98 m depending on the series.

What is the station's resistance to internal arc?

IAC-AB 20 kA 1 s according to IEC 62271-202.

How much does a module weigh and how is it installed?

Approximately 11–65 t. Installation is above ground, on a slope, or partly or fully in the ground.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides