The packaged substation in a Magnelis steel enclosure on a concrete base is designed for 12–24 kV RMU and one or two transformers up to 3150 kVA. It is built in the NS and SC series. A separate compartment for IT equipment is possible.

Medium voltage
12–24 kV (RMU or air insulation)
Transformer
oil-filled or dry-type, up to 3150 kVA; 2 × 1250 kVA
LV switchboard
HMS up to 2500 A
Material
Magnelis on a concrete base

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

On the MV side an RMU or air-insulated switchgear for 12–24 kV is installed. The transformer is oil-filled or dry-type, a single unit up to 3150 kVA, and 2 × 1250 kVA in the two-transformer version. The HMS LV switchboard is rated for currents up to 2500 A. The enclosure has degree of protection IP23D and arc resistance IAC-AB 20 kA 1 s according to IEC 62271-202. Corrosion resistance to category C5 is rated for 30 years, and to C4 for 50 years.

Technical specifications

Medium voltage12–24 kV (RMU or air insulation)
Transformeroil-filled or dry-type, up to 3150 kVA; 2 × 1250 kVA
LV switchboardHMS up to 2500 A
MaterialMagnelis on a concrete base
Degree of protectionIP23D
Corrosion resistanceC5, 30 years / C4, 50 years
Arc resistanceIAC-AB 20 kA 1 s
StandardIEC 62271-202

Request a price and lead time

Packaged substation in a steel enclosure on a concrete base, up to 3150 kVA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8537 20 91 00
HS, 6 digits8537 20
CN (EU)8537 20 91
HTSUS (USA)8537 20 00 20
China customs tariff8537 20 90 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What transformer power does the packaged substation accept?

One transformer up to 3150 kVA or two of 1250 kVA each, oil-filled or dry-type.

What switchgear is installed on the MV side?

An RMU or air-insulated switchgear for 12–24 kV. On the LV side there is an HMS LV switchboard up to 2500 A.

What is the arc and corrosion resistance of the enclosure?

Arc resistance IAC-AB 20 kA 1 s according to IEC 62271-202. Corrosion resistance C5 for 30 years or C4 for 50 years.