Mzb2 / Minibox concrete substation with external operation, 400–1000 kVA

Mzb2 and Minibox concrete substations with external operation are designed for a 400, 630 or 1000 kVA transformer, medium voltage up to 25 kV and an LV side up to 0.69 kV. The series includes models Mzb2 20/400, 20/630, 20/630(1000), version b, a 3×1.65 m variant and Minibox measuring 2.54×1.98 m. Single- and double-transformer variants are available.

Transformer rating
400, 630, 1000 kVA; single- and double-transformer variants
MV / LV voltage
up to 25 kV / up to 0.69 kV
MV / LV switchgear current
630 A / up to 1250 A
Short-time withstand current
up to 25 kA (1 s)

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The substations are equipped with TPM MV switchgear and RN-W LV switchgear. MV switchgear current is 630 A, up to 1250 A on the LV side, and short-time withstand current is up to 25 kA for 1 s. Internal arc withstand corresponds to class IAC-AB-16…20 kA-1 s. The mass of the main module is 6000–8500 kg, the degree of protection of the enclosure is IP 23D, IP 43 on request. Operation is carried out from outside, and personnel do not need to enter the enclosure.

Technical specifications

Transformer rating400, 630, 1000 kVA; single- and double-transformer variants
MV / LV voltageup to 25 kV / up to 0.69 kV
MV / LV switchgear current630 A / up to 1250 A
Short-time withstand currentup to 25 kA (1 s)
Internal arc withstandIAC-AB-16…20 kA-1 s
Mass of main module6000–8500 kg
Degree of protectionIP 23D (IP 43 optional)

Request a price and lead time

Mzb2 / Minibox concrete substation with external operation, 400–1000 kVA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8537 20 91 00
HS, 6 digits8537 20
CN (EU)8537 20 91
HTSUS (USA)8537 20 00 20
China customs tariff8537 20 90 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

What transformer rating is installed in the Mzb2?

A 400, 630 or 1000 kVA transformer. Single- and double-transformer versions are available.

What voltages and currents does the switchgear have?

MV side up to 25 kV with switchgear current 630 A, LV side up to 0.69 kV with current up to 1250 A. Short-time withstand current is up to 25 kA for 1 s.

What are the mass and degree of protection of the main module?

The main module weighs 6000–8500 kg. Degree of protection IP 23D, IP 43 on request.