International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

MRw-bS / MRw-bSP multi-section and multi-storey concrete substation up to 4×1250 / 2×2500 kVA

MRw-bS is assembled from standard interconnected concrete containers for complex substations with several transformers, generators and MV switchgear for primary distribution, including main step-down substations. The multi-storey MRw-bSP version makes it possible to place high capacity on a small area.

Configurations
MRw-bS 20/2×630, 20/2×1250, 20/4×1250; MRw-bSP 20/2×2500
Transformer rating
up to 4000 kVA
Generators
up to 2000 kVA (per project)
Walls
120 mm, fire resistance REI 120

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

Typical configurations are MRw-bS 20/2×630, 20/2×1250 and 20/4×1250, and the multi-storey MRw-bSP 20/2×2500. Transformer rating according to the specifications is up to 4000 kVA, with generators up to 2000 kVA per project. Walls 120 mm thick have fire resistance REI 120. The degree of protection is IP 23D, IP 43 on request. The modular principle makes it possible to assemble a substation of the required configuration from standard blocks.

Technical specifications

ConfigurationsMRw-bS 20/2×630, 20/2×1250, 20/4×1250; MRw-bSP 20/2×2500
Transformer ratingup to 4000 kVA
Generatorsup to 2000 kVA (per project)
Walls120 mm, fire resistance REI 120
Degree of protectionIP 23D (IP 43 optional)

Request a price and lead time

MRw-bS / MRw-bSP multi-section and multi-storey concrete substation up to 4×1250 / 2×2500 kVA. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Customs codes

UKTZED (Ukraine)8537 20 91 00
8537 20 99 00
HS, 6 digits8537 20
CN (EU)8537 20 91
8537 20 99
HTSUS (USA)8537 20 00 40
China customs tariff8537 20 90 00

Codes are for reference: the final code is determined at declaration for the specific model.

Questions and answers

Which configurations of the MRw-bS substation are available?

MRw-bS 20/2×630, 20/2×1250 and 20/4×1250, and the multi-storey MRw-bSP 20/2×2500.

Can generators be installed in the substation?

Yes, generators rated up to 2000 kVA are installed per project.

What are the fire resistance and degree of protection of the enclosure?

Walls 120 mm thick with fire resistance REI 120, degree of protection IP 23D or IP 43 on request.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides