International supply. Engineering expertise.
office@usk.ua09:00–18:00 · Kyiv

FDM252 fieldbus diagnostic module for TPS400 or TS200 systems

The FDM252 is a fieldbus diagnostic module for TPS400 or TS200 systems. It takes its power from the bus and sits in a plug/socket housing. It works with single or redundant trunk power systems and serves one to four non-intrinsically-safe segments.

Model
FDM252
Type
Fieldbus diagnostic module
Systems
TPS400 or TS200
Power
Bus powered

Price, availability and lead time on request. We help with analogue selection, customs clearance and delivery.

Description

The FDM252 is intended for TPS400 or TS200 systems. It is used to raise a master alarm for the fieldbus power system, so it acts as the diagnostic point of the installation.

Power comes from the bus (bus powered). The housing is of the plug/socket type, which keeps fitting and replacement simple. Two versions exist: power supply only, or power supply together with a device coupler.

The module supports a single trunk or a redundant trunk power system. It serves 1, 2, 3 or 4 non-intrinsically-safe segments, meaning segments that do not use intrinsically-safe wiring.

The device coupler approvals are Non-Incendive/Div. 2, Zone 2 and General Purpose. The module is therefore intended for general-purpose areas, Zone 2 and Div. 2 locations.

The catalogue identifies the item by the code FDM252. RoHS compliance is marked as no.

The versions differ in content: in the power-supply-only version the module works as part of the segment power system, while in the combined version, the power supply is combined with the device coupler. The choice depends on how many segments must be served, from one to four, and on whether the power trunk is redundant.

Technical specifications

ModelFDM252
TypeFieldbus diagnostic module
SystemsTPS400 or TS200
PowerBus powered
HousingPlug/socket
VersionPower supply only; power supply with device coupler
Trunk power systemSingle trunk; redundant trunk
Device coupler approvalsNon-Incendive/Div. 2, Zone 2, General Purpose
Non-intrinsically-safe segments1, 2, 3, 4

Part numbers

Show all part numbers (1)

FDM252

How it compares with similar models

ParameterFDM252 fieldbus diagnostic module for TPS400 or TS200 systemsSPM201 surge protection module for fieldbus trunk cablesTPS202 Trunkguard fieldbus segment power conditionerTS200 TRUNKSAFE host interface kit for DeltaV, up to two segments
TypeFieldbus diagnostic moduleSurge protection moduleFieldbus segment power conditionerHost interface kit
HousingPlug/socketPlug/socketPlug/socketDIN rail
Trunk power systemSingle trunk; redundant trunkSingle trunk; redundant trunkSingle trunk; redundant trunkRedundant trunk

Request a price and lead time

FDM252 fieldbus diagnostic module for TPS400 or TS200 systems. We reply within one business day.

* — required fields

Or email sales@usk.ua or call 044 339-50-20.

Questions and answers

Which systems is the FDM252 made for?

TPS400 or TS200 systems. It is a bus-powered fieldbus diagnostic module.

How many segments does it serve?

One, two, three or four non-intrinsically-safe segments, depending on the power system version.

Which trunk power arrangements are supported?

Single trunk and redundant trunk.

Similar equipment from other manufacturers

LET’S CONNECT

Let’s start with your challenge.

Complete a short brief. We will prepare an email you can send from your own email app.

Call us044 339-50-2009:00–18:00
USK ENERGY / SEARCH

Search

Solutions, specialist directions and guides